Why the study?
Estimating pulmonary artery wedge pressure with echocardiography by including left atrial volume (ePAWP-LA) may be misleading, motivating the derivation and validation of an estimate without left atrial volume information (ePAWP-NOLA).
Does ePAWP-NOLA accurately estimate PAWP and predict outcomes compared to ePAWP-LA and ASE/EACVI algorithms?
Does ePAWP-NOLA accurately estimate PAWP and predict outcomes compared to ePAWP-LA and ASE/EACVI algorithms?
Answers are grounded in this paper and cite their sources.
ePAWP-NOLA provides diagnostic and prognostic performance for estimating PAWP that is comparable to ePAWP-LA and superior to the ASE/EACVI diastolic dysfunction algorithm.
Aims: A quantitative estimate of pulmonary artery wedge pressure (PAWP) can be obtained using echocardiography, but including left atrial (LA) volume (ePAWP-LA) in the estimation may be misleading. We aimed to derive and validate a new estimate without LA volume information (ePAWP-NOLA) and compare its performance to the ASE/EACVI algorithms for diastolic dysfunction. Methods and results: = 116, 51 ± 14 years, 69% males, 89% with LVEF < 50%), PAWP agreed with both ePAWP-NOLA and ePAWP-LA (difference 1.3 ± 6.1, 3.2 ± 6.3 mmHg, respectively). PAWP > 15 mmHg was accurately detected by both ePAWP-NOLA and ePAWP-LA [area under the curve: AUC (95%CI): 0.84 (0.76-0.92), 0.80 (0.72-0.88)]. AUC for the ASE/EACVI algorithm was lower [0.69 (0.61-0.77)]). ePAWP-NOLA and ePAWP-LA correlated with right ventricular afterload and were associated with death or implantation of left ventricular assist device, and with cardiovascular death in NEDA. Conclusion: ePAWP-NOLA has diagnostic and prognostic performance comparable to ePAWP-LA, and improved diagnostic performance compared to the ASE/EACVI diastolic dysfunction algorithm.
No takes yet. Share an insight, caveat, or question.
Lindow et al. (2025) studied this question.