Why the study?
The prognostic value of the coronary lumen volume to myocardial mass ratio for predicting MACE in patients undergoing TAVR was unknown.
Does a low coronary lumen volume to myocardial mass (V/M) ratio predict major adverse cardiovascular events in patients undergoing TAVR?
Does a low coronary lumen volume to myocardial mass (V/M) ratio predict major adverse cardiovascular events in patients undergoing TAVR?
A low coronary lumen volume to myocardial mass ratio (≤ 33.31 mm³/g) derived from pre-procedural CT is an independent predictor of MACE in patients undergoing TAVR.
Answers are grounded in this paper and cite their sources.
Low V/M ratio may aid TAVR risk stratification; hypothesis-generating and requires prospective validation before clinical use.
BACKGROUND: The coronary lumen volume to myocardial mass (V/M) ratio has been suggested as a quantitative metric of potential imbalance between coronary blood supply and myocardial oxygen demand. This study was designed to assess the prognostic value of the V/M ratio for predicting major adverse cardiovascular events (MACE) in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS: This study enrolled patients who received a standard planning computed tomography (CT) scan before TAVR and dichotomized at the median of 33.31 mm³/g of V/M ratio into groups with low V/M ratio and high V/M ratio. The V/M ratio was calculated by coronary computed tomography angiography (CTA). The endpoint was a composite of all-cause mortality, stroke, and hospitalization for heart failure. The cumulative incidence of the MACE was compared using Kaplan-Meyer plots and uni- and multivariate Cox proportional hazards regression analysis. RESULTS: /g, P<0.001). Multivariate Cox proportional hazards regression showed that the low V/M ratio group (≤ 33.31 mm³/g) had a higher risk of MACE after TAVR (HR: 6.14, 95%CI: 1.37-27.54; P = 0.018). CONCLUSIONS: The lower V/M ratio could serve as an independent predictor of MACE in patients undergoing TAVR. CLINICAL TRIAL NUMBER: Not applicable.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: