Systematic review evaluates alignment discrepancies in knee imaging, suggesting critical considerations for surgeons.
OBJECTIVE: To determine whether substantial differences in coronal plane alignment of the knee phenotype distribution, as well as systematic angular measurement discrepancies, exist between CT and long-leg radiography. MATERIALS AND METHODS: From February 2021 to April 2025, we searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials for studies comparing CT- and long-leg radiography-derived coronal plane alignment classifications of the knee in patients with osteoarthritis. The primary outcome was distribution of coronal plane alignment phenotypes. Secondary outcomes included differences in medial proximal tibial angle, lateral distal femoral angle, arithmetic hip-knee-ankle angle, and joint line obliquity. CONCLUSION: Discrepancies between CT-based software-generated and long-leg radiography-derived measurements substantially affect coronal plane alignment classification and angular parameters. Surgeons should consider these modality-specific variations and employ compensatory verification strategies to ensure optimal alignment.
No takes yet. Share an insight, caveat, or question.
Bian et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: