May 6, 20260 citations

Assessment of Commutability in Factor VIII Activity Testing Using Fresh Human Plasma Samples.

View Full Paper
LVLaura VierbaumGerman Sport University CologneMWMichael WeigandLudwig-Maximilians-Universität MünchenMGMira GanslmeierLudwig-Maximilians-Universität München

Key Points

  • To evaluate the commutability of factor VIII activity testing materials for accurate diagnostics.
  • Measured FVIII activity in 97 native plasma samples using clotting tests and chromogenic assays.
  • Analyzed frozen and lyophilized aliquots alongside commercially available control materials.
  • Assessed commutability using Bland-Altman plots comparing candidate materials with native plasma measurements.
  • Good agreement in FVIII activity measurements across four methods for native plasma.
  • Mean differences after lyophilization were more pronounced but within commutability criteria.
  • All EQAMs evaluated were deemed commutable for their intended use.

Abstract

For the diagnosis and therapeutic monitoring of bleeding disorders as well as for thrombotic risk assessment, reliable measurement of factor VIII (FVIII) coagulant activity is required. The complex FVIII structure and limited stability pose major challenges in hemostaseological diagnostics concerning the preanalytical handling and the availability of commutable control and calibrator materials. The aim of this study was to assess the commutability of frozen and lyophilized patient plasma and routinely used external quality assessment materials (EQAMs) for FVIII activity measurement.FVIII activity was measured in 97 native plasma samples covering a broad activity range using clotting tests and chromogenic assays from two manufacturers. Corresponding frozen and lyophilized aliquots as well as four commercially available lyophilized control materials from three manufacturers were analyzed the same way. Commutability was assessed by comparing the mean natural logarithmic differences of candidate materials from those of native plasma using Bland-Altman plots. A commutability criterion was defined with respect to the intended use of the materials as EQAMs, based on the mean ± 2 standard deviations derived from the distribution of natural logarithmic differences in native plasma samples.Native plasma measurements showed good agreement across the four methods. Method-specific effects on FVIII activity measurement were minor after freezing, but more pronounced after lyophilization. Nevertheless, mean differences observed for frozen and lyophilized plasma remained within the predefined commutability criterion. All investigated EQAMs were deemed commutable for their intended use in external quality assessment. All in all, commutability studies for FVIII activity measurement are feasible but resource-intensive.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Vierbaum et al. (2026) studied this question.

synapsesocial.com/papers/69fa983604f884e66b531ee0https://doi.org/10.1055/a-2852-9387
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Performance of Factor <scp>VIII</scp> Extended Half‐Life Product Measurements in External Quality Assessment Programmes2026
  2. 2Effect of increasing the number of repeated measurements on the accuracy of determining factor VIII activity and fibrinogen concentrations in blood plasma2024
  3. 3Monitoring Extended Half‐Life Factor VIII and IX Concentrates: Performance in Routine Clotting‐and Thrombin Generation Assays2026
  4. 4Evaluating Factor VIII Concentrates Using Clot Waveform Analysis2024 · 2 citations
  5. 5Development of a rapid and fully automated factor VIII inhibitor assay, insensitive to emicizumab, and a lowest level of quantification of 0.2 BU/mL2024 · 2 citations