Why the study?
Are LVOT calcification and aggressive annular area oversizing associated with an increased risk of aortic root rupture during balloon-expandable TAVR?
Are LVOT calcification and aggressive annular area oversizing associated with an increased risk of aortic root rupture during balloon-expandable TAVR?
Answers are grounded in this paper and cite their sources.
Moderate to severe LVOT calcification and prosthesis oversizing ≥20% are strong predictors of aortic root rupture during balloon-expandable TAVR.
BACKGROUND: Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. METHODS AND RESULTS: Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters and cross-sectional area of the sinotubular junction, annulus, and LVOT, and the presence, location, and extent of calcification of the LVOT, as well. There were no significant differences between the 2 groups in any preoperative clinical and echocardiographic variables. Aortic root rupture was identified in 20 patients and periaortic hematoma in 11. Patients with root rupture had a higher degree of subannular/LVOT calcification quantified by the Agatston score (181.2±211.0 versus 22.5±37.6, P<0.001), and a higher frequency of ≥20% annular area oversizing (79.4% versus 29.0%, P<0.001) and balloon postdilatation (22.6% versus 0.0%, P=0.005). In conditional logistic regression analysis for the matched data, moderate/severe LVOT/subannular calcifications (odds ratio, 10.92; 95% confidence interval, 3.23-36.91; P<0.001) and prosthesis oversizing ≥20% (odds ratio, 8.38; 95% confidence interval, 2.67-26.33; P<0.001) were associated with aortic root contained/noncontained rupture. CONCLUSIONS: This study demonstrates that LVOT calcification and aggressive annular area oversizing are associated with an increased risk of aortic root rupture during TAVR with balloon-expandable prostheses. Larger studies are warranted to confirm these findings.
No takes yet. Share an insight, caveat, or question.
Barbanti et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: