Why the study?
Mechanically actuated steerable catheters used in dynamic cardiac environments face several mechanical limitations that need to be understood to develop catheters with increased steerability.
A novel multi-steerable catheter prototype with four degrees of freedom was developed to overcome key mechanical limitations of conventional catheters, potentially enabling more complex and patient-specific cardiac interventions.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for advanced catheter navigation; leaves open clinical feasibility and safety in human cardiac procedures.
In recent years, steerable catheters have been developed to combat the effects of the dynamic cardiac environment. Mechanically actuated steerable catheters appear the most in the clinical setting; however, they are bound to a number of mechanical limitations. The aim of this research is to gain insight in these limitations and use this information to develop a new prototype of a catheter with increased steerability. The main limitations in mechanically steerable catheters are identified and analysed, after which requirements and solutions are defined to design a multi-steerable catheter. Finally, a prototype is built and a proof-of-concept test is carried out to analyse the steering functions. The mechanical analysis results in the identification of five limitations: (1) low torsion, (2) shaft shortening, (3) high unpredictable friction, (4) coupled tip-shaft movements, and (5) complex cardiac environment. Solutions are found to each of the limitations and result in the design of a novel multi-steerable catheter with four degrees of freedom. A prototype is developed which allows the dual-segmented tip to be steered over multiple planes and in multiple directions, allowing a range of complex motions including S-shaped curves and circular movements. A detailed analysis of limitations underlying mechanically steerable catheters has led to a new design for a multi-steerable catheter for complex cardiac interventions. The four integrated degrees of freedom provide a high variability of tip directions, and repetition of the bending angle is relatively simple and reliable. The ability to steer inside the heart with a variety of complex shaped curves may potentially change conventional approaches in interventional cardiology towards more patient-specific and lower complexity procedures. Future directions are headed towards further design optimizations and the experimental validation of the prototype.
No takes yet. Share an insight, caveat, or question.
Ali et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: