The classical Shewhart c-chart and p-chart which are constructed based on the Poisson and binomial distributions are inappropriate in monitoring zero-inflated counts. They tend to underestimate the dispersion of zero-inflated counts and subsequently lead to higher false alarm rate in detecting out-of-control signals. Another drawback of these charts is that their 3-sigma control limits, evaluated based on the asymptotic normality assumption of the attribute counts, have a systematic negative bias in their coverage probability. We recommend that the zero-inflated models which account for the excess number of zeros should first be fitted to the zero-inflated Poisson and binomial counts. The Poisson parameter λ estimated from a zero-inflated Poisson model is then used to construct a one-sided c-chart with its upper control limit constructed based on the Jeffreys prior interval that provides good coverage probability for λ. Similarly, the binomial parameter p estimated from a zero-inflated binomial model is used to construct a one-sided np-chart with its upper control limit constructed based on the Jeffreys prior interval or Blyth–Still interval of the binomial proportion p. A simple two-of-two control rule is also recommended to improve further on the performance of these two proposed charts.
No takes yet. Share an insight, caveat, or question.
Sim et al. (2008) studied this question.