Why the study?
Only 20% of emergency admissions for chest pain have an acute myocardial infarction, and high-sensitivity cardiac troponin assays may enable rapid rule-out to avoid unnecessary hospital admissions.
Are high-sensitivity cardiac troponin assays clinically effective and cost-effective compared with standard troponin testing for early rule-out of acute myocardial infarction in adults presenting with acute chest pain?
Are high-sensitivity cardiac troponin assays clinically effective and cost-effective compared with standard troponin testing for early rule-out of acute myocardial infarction in adults presenting with acute chest pain?
High-sensitivity cardiac troponin testing is a cost-effective strategy for the early rule-out of acute myocardial infarction in adults with acute chest pain.
Answers are grounded in this paper and cite their sources.
Supports hs-cTnI early rule-out in ED chest pain; confirms cost-effectiveness over standard testing in Level 1 evidence.
BACKGROUND: Early diagnosis of acute myocardial infarction is important, but only 20% of emergency admissions for chest pain will actually have an acute myocardial infarction. High-sensitivity cardiac troponin assays may allow rapid rule out of myocardial infarction and avoid unnecessary hospital admissions. OBJECTIVES: To assess the clinical effectiveness and cost-effectiveness of high-sensitivity cardiac troponin assays for the management of adults presenting with acute chest pain, in particular for the early rule-out of acute myocardial infarction. METHODS: Sixteen databases were searched up to September 2019. Review methods followed published guidelines. Studies were assessed for quality using appropriate risk-of-bias tools. The bivariate model was used to estimate summary sensitivity and specificity for meta-analyses involving four or more studies; otherwise, random-effects logistic regression was used. The health economic analysis considered the long-term costs and quality-adjusted life-years associated with different troponin testing methods. The de novo model consisted of a decision tree and a state-transition cohort model. A lifetime time horizon (of 60 years) was used. RESULTS: High-Sensitivity Troponin I (Siemens Healthcare, Erlangen, Germany) (< 5 ng/l at 0 hours AND Δ < 2 ng/l at 0 to 1 hours) would be cost-effective. CONCLUSIONS: High-sensitivity cardiac troponin testing may be cost-effective compared with standard troponin testing. STUDY REGISTRATION: This study is registered as PROSPERO CRD42019154716. FUNDING: ; Vol. 25, No. 33. See the NIHR Journals Library website for further project information.
No takes yet. Share an insight, caveat, or question.
Westwood et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: