Why the study?
Although complete CIED removal is recommended for CIED infections, an up-to-date and comprehensive assessment of evidence evaluating its effect was needed.
Does complete CIED extraction reduce reinfection/relapse and mortality in patients with CIED infection compared to conservative therapy?
Does complete CIED extraction reduce reinfection/relapse and mortality in patients with CIED infection compared to conservative therapy?
Complete CIED extraction in patients with device infections is associated with significantly lower rates of reinfection and mortality compared to conservative therapy.
Answers are grounded in this paper and cite their sources.
Supports complete CIED extraction to reduce relapse and mortality in device infections; extends observational evidence but leaves open randomized confirmation.
BACKGROUND: Complete removal of cardiac implantable electronic devices (CIEDs) is recommended in patients with CIED infections, including both systemic and localized pocket infection. The aim of the study was to provide an up-to-date and comprehensive assessment of evidence relating to the effect of complete CIED extraction in patients with a CIED infection. METHODS: We performed a systematic review and meta-analysis of studies reporting short- and mid-term outcomes in patients who had a device infection or infective endocarditis (IE) and underwent complete removal of the cardiac device (generator and leads) compared to those who received conservative therapy (no removal, partial removal, local antibiotic infiltration or isolated antibiotic therapy). The primary outcome was reinfection/relapse. Secondary outcomes were short-term (30-day/in-hospital) and mid-term (mean follow-up: 43.0 months) mortality. Random effects model was performed. RESULTS: Thirty-two studies met the criteria for inclusion in the final analysis. Patients with complete CIED extraction (n = 905) exhibited a lower rate of relapse/re-infection compared to patients (n = 195) with a conservative treatment approach (n = 195, OR 0.02, 95%CI 0.01-0.06, p < 0.0001, mean-follow-up: 16.1 months). Additionally, these patients displayed a lower short- (OR 0.40, 95%CI 0.23-0.69, p = 0.01) and mid-term (OR 0.52, 95%CI 0.34-0.78, p = 0.002) mortality. CONCLUSIONS: The analysis indicates that patients with a CIED infection who undergo complete CIED extraction exhibit a lower rate of relapse/re-infection. Additionally, a lower short- and mid-term mortality is observed, although it is acknowledged that this outcome may be influenced by treatment allocation bias.
No takes yet. Share an insight, caveat, or question.
Caldonazo et al. (2024) studied this question.