Why the study?
Transthoracic echocardiographic estimation of Qp/Qs is routinely used and guideline-recommended, but its real-world applicability needed assessment, particularly for hemodynamically significant shunt lesions.
Does transthoracic echocardiography-derived Qp/Qs accurately correlate with oximetry-derived Qp/Qs in patients with atrial septal defects?
Does transthoracic echocardiography-derived Qp/Qs accurately correlate with oximetry-derived Qp/Qs in patients with atrial septal defects?
Despite being included in guidelines, TTE-derived Qp/Qs correlates poorly with invasive oximetry and tends to overestimate left-to-right shunts in patients with atrial septal defects.
Answers are grounded in this paper and cite their sources.
TTE Qp/Qs should not yet guide ASD shunt decisions; leaves open need for validated noninvasive alternatives versus oximetry.
Background: Transthoracic echocardiographic (TTE) estimation of the pulmonary to systemic flow ratio (Qp/Qs) is routinely used in clinical practice and is included in the American Society of Echocardiography Guidelines. We sought to assess its real-world applicability with a particular focus on hemodynamically significant shunt lesions. Bland-Altman plots demonstrated poor agreement between the predetermined limits of agreement (-0.5-1.5). Conclusion: Transthoracic echocardiography estimated Qp/Qs, although routinely utilized in clinical practice, has poor correlation and agreement with oximetry-derived Qp/Qs. The test performs poorly in all age groups in detecting a hemodynamically significant shunt and tends to overestimate the degree of left to right shunt.
No takes yet. Share an insight, caveat, or question.
Faherty et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: