Why the study?
Evaluating long-term inflammatory response and function after aortic valve replacement is important to help prevent reoperation and improve prosthesis durability and functionality.
Does the type of prosthesis (bioprosthesis vs mechanical) affect long-term inflammatory response and functionality in patients undergoing aortic valve replacement?
Does the type of prosthesis (bioprosthesis vs mechanical) affect long-term inflammatory response and functionality in patients undergoing aortic valve replacement?
Long-term inflammatory markers differ between mechanical and biological aortic prostheses and are associated with valve dysfunction, suggesting a potential target to prolong prosthesis functionality.
Answers are grounded in this paper and cite their sources.
Inflammatory marker differences by prosthesis type and links to dysfunction are hypothesis-generating; prospective studies needed before clinical adoption.
BACKGROUND: The evaluation of long-term inflammatory response and function in postoperative patients with aortic valve replacement (AVR) deserves special analysis because it is important to try to prevent reoperation and improve durability and functionality of the prostheses. It is our objective METHODS: In this study, we included a cohort of patients with aortic valve damage treated by AVR with mechanical prosthesis, bio prosthesis and we included a control group. RESULTS: We found that IL-4 and osteopontin levels were higher in patients with mechanical vs biological prostheses (p=0.01 and p=0.04, respectively), osteoprotegerin (OPG) levels were decreased (p=0.01), women had lower levels of ET-1 and IL-6, (p=0.02) (p=0.04), respectively. Patients older than 60 years had decreased levels of IL-1ß p<0.001) and a higher concentration of IL-4 p<0.05). IL-1ß, OPG and TNFα were higher in patients with less than 5 years of evolution vs more than 10 years (p=0.004, p=0.02 and p=0.03, respectively). Factors such as age, gender, prosthetic and elevated IL-1B and ET-1 levels are associated with valve dysfunction prosthetic. These results indicate that the inflammatory involvement present prior to valve replacement may be perpetuated by various factors in the long term. CONCLUSIONS: The findings provide us with the opportunity to effectively treat patients with AVR in the postoperative period, which could prolong the functionality of the bio prostheses. TRIAL REGISTRATION NUMBER: NCT04557345.
No takes yet. Share an insight, caveat, or question.
Saucedo‐Orozco et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: