Why the study?
Cardiac conduction disturbance is the most frequent complication following TAVR, and whether membranous septum anatomy provides useful information about this risk with a balloon-expandable valve was examined.
Does preoperative CT assessment of membranous septal anatomy predict conduction disturbance in patients undergoing TAVR with a balloon-expandable valve?
Does preoperative CT assessment of membranous septal anatomy predict conduction disturbance in patients undergoing TAVR with a balloon-expandable valve?
Answers are grounded in this paper and cite their sources.
CT assessment of membranous septum length may identify TAVR patients at risk for conduction disturbance; extends prior observations but requires prospective confirmation.
BACKGROUND: Cardiac conduction disturbance (CD) is the most frequent complication following transcatheter aortic valve replacement (TAVR). This study examined whether the anatomy of the membranous septum (MS) could provide useful information about the risk of CD following TAVR with a balloon-expandable valve (BEV). METHODS AND RESULTS: Among 132 consecutive patients, 106 (mean age, 85.6±5.1 years; 75 females) were included in the study. Using preoperative CT and angiography, MS length and implantation depth (ID) were assessed. The MS length minus the prosthesis ID was calculated (∆MSID). Correlation between CD, defined as new-onset left-bundle branch block (LBBB) or the need for permanent pacemaker (PPM) within 1 week after the procedure, and MS length were evaluated. A total of 19 patients (18%) developed CD following TAVR. MS length was significantly shorter in these patients than in those without CD (5.3±1.3 vs. 6.6±1.4; P<0.001), and was the important predictor of CD (odds ratio [OR]: 0.43, 95% confidence interval [CI]: 0.27-0.69, P<0.001). When considering the pre- and postprocedural parameters, the ∆MSID was smaller in patients with CD (-1.7±1.5 vs. 0.8±1.9, P<0.001), and emerged as the important predictor of CD (OR: 0.47, 95% CI: 0.33-0.69, P<0.001). CONCLUSIONS: Short MS is associated with an increased risk of CD after TAVR with BEV.
No takes yet. Share an insight, caveat, or question.
Miki et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: