Key result
Software-based Qp:Qs simulation shows no systematic difference versus conventional Doppler estimates.
Why the study?
Conventional echocardiographic Qp:Qs estimation in ASD is limited by operator dependency, Doppler alignment sensitivity, and measurement errors, prompting evaluation of simulation-based haemodynamic modelling.
Does software-based haemodynamic simulation modelling provide comparable Qp:Qs quantification to conventional Doppler echocardiography in patients with atrial septal defect?
Observational (n=94)
No
Does software-based haemodynamic simulation modelling provide comparable Qp:Qs quantification to conventional Doppler echocardiography in patients with atrial septal defect?
A novel 3D haemodynamic simulation software provides feasible Qp:Qs estimates in ASD patients with no systematic difference compared to conventional Doppler methods, though only 53% of cases fell within a 20% deviation range.
Answers are grounded in this paper and cite their sources.
Requires caution in noninvasive Qp:Qs for ASD decisions; leaves open simulation modelling's role pending outcome validation.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Gross et al. (2026) conducted an observational in Atrial septal defect (n=94). Software-based Qp:Qs quantification (haemodynamic simulation model) vs. Conventional Doppler-derived Qp:Qs quantification was evaluated on Mean Qp:Qs. Software-based haemodynamic simulation for Qp:Qs quantification yielded a mean of 1.73, showing no systematic difference compared to conventional Doppler-derived estimates (mean 1.83).