Why the study?
Stroke is a major complication following TAVI, but it remains unknown whether the valve deployment system itself impacts the incidence of early stroke.
Does the use of self-expandable valves compared to balloon-expandable valves reduce the 30-day incidence of stroke in patients undergoing transfemoral TAVI?
Does the use of self-expandable valves compared to balloon-expandable valves reduce the 30-day incidence of stroke in patients undergoing transfemoral TAVI?
Self-expandable valves may be associated with a lower 30-day incidence of stroke compared to balloon-expandable valves after transfemoral TAVI, though network analysis did not confirm the superiority of a specific valve system.
Answers are grounded in this paper and cite their sources.
May support self-expandable valve selection to reduce 30-day stroke after TAVI; extends aggregate evidence while leaving specific device comparisons open.
AIMS: Stroke is a major complication after transcatheter aortic valve implantation (TAVI). Although multifactorial, it remains unknown whether the valve deployment system itself has an impact on the incidence of early stroke. We performed a meta- and network analysis to investigate the 30-day stroke incidence of self-expandable (SEV) and balloon-expandable (BEV) valves after transfemoral TAVI. METHODS AND RESULTS: Overall, 2723 articles were searched directly comparing the performance of SEV and BEV after transfemoral TAVI, from which 9 were included (3086 patients). Random effects models were used for meta- and network meta-analysis based on a frequentist framework. Thirty-day incidence of stroke was 1.8% in SEV and 3.1% in BEV (risk ratio of 0.62, 95% confidence interval (CI) 0.49-0.80, p = 0.004). Treatment ranking based on network analysis (P-score) revealed CoreValve with the best performance for 30-day stroke incidence (75.2%), whereas SAPIEN had the worst (19.0%). However, network analysis showed no inferiority of SAPIEN compared with CoreValve (odds ratio 2.24, 95% CI 0.70-7.2). CONCLUSION: Our analysis indicates higher 30-day stroke incidence after transfemoral TAVI with BEV compared to SEV. We could not find evidence for superiority of a specific valve system. More randomized controlled trials with head-to-head comparison of SEV and BEV are needed to address this open question.
No takes yet. Share an insight, caveat, or question.
Seppelt et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: