Answers are grounded in this paper and cite their sources.
In this paper, selective harmonic mitigation (SHM) and selective harmonic elimination (SHE) modulation techniques have been combined to produce appropriate pulses for a four-leg three-level neutral point clamped (NPC) inverter. In the proposed hybrid method, the SHM technique is applied to phase legs in order to mitigate non-triplen harmonics (fifth, seventh, . . .), and the fourth leg is controlled by the SHE principle to eliminate important low-order triplen harmonics (third, ninth, . . .) completely. In this context, it is demonstrated that using SHM instead of an SHE modulator for phase legs leads to a reduced vast range of harmonic orders in the NPC output voltage, significantly. Moreover, it is proved that the presented hybrid switching technique has the ability of dc-bus capacitor voltage balancing, inherently. Furthermore, analyses are performed to calculate the dc-bus capacitances accurately to show 5% voltage ripple acceptably. Simulation and experimental results validate a good dynamic performance of the proposed hybrid modulation technique in firing the NPC inverter switches to generate low-harmonic voltage waveforms supplying balanced and unbalanced loads while balancing the dc capacitor voltages in a four-wire network with small dc-link capacitors.
No takes yet. Share an insight, caveat, or question.
Sharifzadeh et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: