Why the study?
Traditional transvenous pacemakers cause worsening tricuspid valve function and ventricular dysfunction, but the association of leadless pacing with ventricular and valvular function has not been well established.
Does leadless pacemaker placement affect valvular regurgitation and ventricular function in patients requiring pacing?
Does leadless pacemaker placement affect valvular regurgitation and ventricular function in patients requiring pacing?
Leadless pacing does not worsen tricuspid regurgitation in the short term, but is associated with a reduction in biventricular function similar to traditional right ventricular pacing.
Answers are grounded in this paper and cite their sources.
May not spare ventricular function despite avoiding tricuspid regurgitation; leaves open comparative effects versus traditional pacing.
BACKGROUND: Traditional transvenous pacemakers are associated with worsening tricuspid valve function due to lead-related leaflet impingement, as well as ventricular dysfunction related to electromechanical dyssynchrony from chronic right ventricular (RV) pacing. The association of leadless pacing with ventricular and valvular function has not been well established. We aimed to assess the association of leadless pacemaker placement with changes in valvular regurgitation and ventricular function. METHODS AND RESULTS: Echocardiographic features before and after leadless pacemaker implant were analyzed in consecutive patients who received a leadless pacemaker with pre- and postprocedure echocardiography at Duke University Hospital between November 2014 and November 2019. Valvular regurgitation was graded ordinally from 0 (none) to 3 (severe). Among 54 patients, the mean age was mean age was 70.1 ± 14.3 years, 24 (44%) were women, and the most frequent primary pacing indication was complete heart block in 24 (44%). The median RV pacing burden was 45.4 (interquartile range [IQR] 3.5-97.0). On echocardiogram performed 8.9 months (IQR 4.5-14.5) after implant, there was no change in the average severity of tricuspid regurgitation (mean change 0.07 ± 1.15, p = .64) from pre-procedure echocardiogram. We observed a decrease in the average left ventricular ejection fraction (LVEF) (52.3 ± 9.3 to 47.9 ± 12.1, p = .0019) and tricuspid annular plane systolic excursion (TAPSE) (1.8 ± 0.6 to 1.6 ± 0.4, p = .0437). Thirteen patients (24%) had absolute drop in LVEF of ≥10%. CONCLUSION: We did not observe short term worsening valvular function in patients with leadless pacemakers. However, consistent with the pathophysiologic impact of RV pacing, leadless pacing was associated with a reduction in biventricular function.
No takes yet. Share an insight, caveat, or question.
Arps et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: