Why the study?
Characteristics and outcomes of patients with low-flow low-gradient aortic stenosis undergoing TAVI are poorly understood.
Does TAVI yield different short-term and long-term outcomes in patients with low-flow low-gradient aortic stenosis compared to high-gradient aortic stenosis?
Does TAVI yield different short-term and long-term outcomes in patients with low-flow low-gradient aortic stenosis compared to high-gradient aortic stenosis?
While TAVI provides similar short-term procedural success and symptomatic improvement across aortic stenosis subtypes, long-term mortality remains significantly higher in patients with low-flow low-gradient aortic stenosis compared to those with high-gradient disease.
Answers are grounded in this paper and cite their sources.
Higher long-term mortality in LFLG AS after TAVI warrants cautious prognostication; leaves open subtype-specific strategies for prospective evaluation.
OBJECTIVES: The study objective was to characterize different groups of low-flow low-gradient (LFLG) aortic stenosis (AS) and determine short-term outcomes and long-term mortality according to Valve Academic Research Consortium-3 (VARC-3) endpoint definitions. BACKGROUND: Characteristics and outcomes of patients with LFLG AS undergoing transcatheter aortic valve implantation (TAVI) are poorly understood. METHODS: ). RESULTS: We included 1776 patients (956 HG, 447 cLFLG, and 373 pLFLG patients). Most baseline characteristics differed significantly. Median Society of Thoracic Surgeons (STS) score was highest in cLFLG, followed by pLFLG and HG patients (5.0, 3.9 and 3.0, respectively, p < 0.01). Compared to HG patients, odds ratios for the short-term VARC-3 composite endpoints, technical failure (cLFLG, 0.76 [95% confidence interval, 0.40-1.36], pLFLG, 1.37 [0.79-2.31]) and device failure (cLFLG, 1.06 [0.74-1.49], pLFLG, 0.97 [0.66-1.41]) were similar, without relevant differences within LFLG patients. NYHA classes improved equally in all groups. Compared to HG, LFLG patients had a higher 3-year all-cause mortality (STS score-adjusted hazard ratios, cLFLG 2.16 [1.77-2.64], pLFLG 1.53 [1.22-193]), as well as cardiovascular mortality (cLFLG, 2.88 [2.15-3.84], pLFLG, 2.08 [1.50-2.87]). CONCLUSIONS: While 3-year mortality remains high after TAVI in LFLG compared to HG patients, symptoms improve in all subsets after TAVI.
No takes yet. Share an insight, caveat, or question.
Steffen et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: