Key result
Conservative management of 40-44 mm aortas during SAVR in BAV shows similar survival to <40 mm.
Why the study?
The optimal management of ascending aortas measuring 40-44 mm in patients with bicuspid aortic valve undergoing surgical aortic valve replacement remains debated.
Does conservative management of the ascending aorta result in safe aortic dilation rates and survival in patients with bicuspid aortic valve and aorta diameters of 40-44 mm undergoing SAVR?
Observational (n=88)
Does conservative management of the ascending aorta result in safe aortic dilation rates and survival in patients with bicuspid aortic valve and aorta diameters of 40-44 mm undergoing SAVR?
Conservative management of ascending aortas measuring 40-44 mm during SAVR in bicuspid aortic valve patients is safe and associated with minimal dilation over 5 years.
Answers are grounded in this paper and cite their sources.
Conservative management of 40-44 mm aortas was associated with similar survival; leaves open confirmation in prospective trials before practice change.
AIM Bicuspid aortic valve (BAV) is a common congenital heart defect often associated with ascending aorta dilation. Current guidelines suggest surgical intervention for diameters ≥45 mm in conjunction with surgical aortic valve replacement (SAVR). However, the optimal management of ascending aortas measuring 40-44 mm remains under debate. This study aims to evaluate the evolution of aortic diameter in patients with BAV and ascending aorta diameters between 40 and 44 mm undergoing aortic valve replacement, assessing whether a conservative approach is justified. METHOD We conducted a retrospective observational study, analysing 88 patients with BAV who underwent SAVR between January 2012 and December 2018. Patients were divided into two groups based on preoperative ascending aorta diameters: <40 mm (Group 1, n=15) and the ≥40 and <45 mm (Group 2, n=11). Follow-up of at least 5 years included aortic dilation rates, survival, and reoperation rates. RESULTS No significant differences were observed in aortic dilation between the two groups during follow-up, with overall annual dilation rates of 0.2±0.07 mm/year. Survival rates were 86.3% for Group 1 and 81.9% for Group 2, with no reoperations required in either group. CONCLUSIONS Patients with BAV and ascending aorta diameters of 40-44 mm do not require prophylactic aortic replacement during AVR, provided they undergo regular follow-up. These findings support current guidelines advocating conservative management for ascending aorta diameters in this range. However, in younger patients or those nearing the 45 mm threshold, surgical replacement may still be considered to pre-empt future complications.
No takes yet. Share an insight, caveat, or question.
Hamameh et al. (2026) conducted an observational in Bicuspid aortic valve (BAV) undergoing surgical aortic valve replacement (n=88). Conservative management of ascending aorta (diameter 40-44 mm) vs. Ascending aorta diameter <40 mm was evaluated on Survival rate. Conservative management of ascending aorta diameters of 40-44 mm during surgical aortic valve replacement in bicuspid aortic valve patients yielded similar survival to those <40 mm.
Synapse has enriched 10 related papers. Consider them for comparative context: