Key result
Negative non-verbal feedback elicits a ~181 msec decrease in RRI during presentations vs no feedback.
Why the study?
Does non-verbal performance feedback during a presentation affect heart rate variability and emotional stress responses in university students?
RCT (n=15)
Randomized
No
Does non-verbal performance feedback during a presentation affect heart rate variability and emotional stress responses in university students?
Absolute Event Rate: 181.4% vs 48.4%
Non-verbal negative feedback from an audience during a presentation increases physiological stress responses (reduced RRI) more than positive or no feedback.
Negative non-verbal feedback may heighten acute stress in presenters; extends social evaluation research to real-time audience interactions via RCT.
The selective detection of different metal-ion pollutants is of great significance for assessing water quality and investigating pollution sources. To address this issue, a composite suspension of zeolitic imidazolate framework-8 and β-cyclodextrin (ZIF-8@β-CD) and functionalized a prism-based surface plasmon resonance (SPR) sensor with the suspension via drop casting has been prepared for the selective detection of Cu²⁺ in water. The interaction between ZIF-8 and Cu²⁺ is mainly related to ion exchange and coordination interaction, while the hydroxyl group on the surface of cavity-structured β-CD confers excellent selective binding ability with Cu²⁺. Based on these combined effects, the maximum resonance wavelength shift of the ZIF-8@β-CD-functionalized SPR sensor was 23.03 nm within a Cu²⁺ concentration range of 0-320 µM, while that was merely 5.12 nm for the sensor modified with ZIF-8 alone. Additionally, the introduction of β-CD produces a synergistic effect with ZIF-8, significantly enhancing the sensor's selective capture capacity for Cu²⁺ relative to the tested interfering metal ions, including Cd²⁺, Zn²⁺, Cr³⁺, Fe³⁺, Co²⁺, Mn²⁺, Ca²⁺, and Mg²⁺. Consequently, the resonance wavelength shift showed a good linear relationship with Cu²⁺ concentration over the range 0-80 µM, yielding a sensitivity of 0.2 nm/µM and a LOD of 4.35 µM. This study presents a novel, straightforward strategy for functionalizing SPR sensor interfaces to enable high-performance, selective detection of Cu²⁺, with significant value for aquatic ecosystem monitoring and freshwater resource safety.
No takes yet. Share an insight, caveat, or question.
Ichikawa et al. (2025) conducted an RCT in Psychological and physiological stress (n=15). Non-verbal feedback (positive or negative) vs. No face-to-face feedback (video recording) was evaluated on Decrease in R-R interval (RRI) during task.
Synapse has enriched 5 related papers. Consider them for comparative context: