Key result
AI-guided single-lead ECG screening increases AF detection by ~2.3 per 100 person-years in high-risk patients.
Why the study?
Current AF screening approaches using a guideline age-based threshold of ≥65 years have shown limited yield. Whether the AF screening effect is larger among individuals identified as at elevated risk by validated clinical and ECG-based AI risk models was evaluated.
Does risk stratification using clinical and artificial intelligence-enabled 12-lead ECG models identify high-risk older adults who experience a greater yield of incident atrial fibrillation diagnosis from single-lead ECG screening compared to usual care?
RCT (n=16,937)
Open-label
Cluster-randomized 1:1
Yes
Does risk stratification using clinical and artificial intelligence-enabled 12-lead ECG models identify high-risk older adults who experience a greater yield of incident atrial fibrillation diagnosis from single-lead ECG screening compared to usual care?
Combining an AI-enabled 12-lead ECG model with the CHARGE-AF clinical score effectively stratifies 2-year AF risk in older primary care patients and identifies a high-risk top decile in whom point-of-care single-lead ECG screening yields a significant increase in new AF diagnoses (NNS=43/year).
Answers are grounded in this paper and cite their sources.
Supports targeted single-lead ECG screening in top CH-AI decile (NNS 43); extends AI-clinical risk stratification to primary care RCTs.
BACKGROUND: Screening for atrial fibrillation (AF) may lead to earlier detection and initiation of preventive measures. Current AF screening approaches using a guideline age-based threshold of ≥65 years have shown limited yield. OBJECTIVES: In an AF screening trial, we assessed whether the screening effect was larger among individuals at elevated AF risk using validated clinical and electrocardiogram (ECG)-based artificial intelligence (AI) risk models. METHODS: VITAL-AF was a cluster-randomized trial of patients aged ≥65 years treated at 1 of 16 primary care practices affiliated with Massachusetts General Hospital. Patients randomized to a screening practice were screened using a single-lead ECG. Among VITAL-AF participants without prevalent AF with at least one 12-lead ECG within 3 years before enrollment, we estimated AF risk using 3 validated models derived outside of VITAL-AF: the Cohorts of Heart and Aging Research in Genomic Epidemiology-AF (CHARGE-AF) clinical score, an AI-based model using a 12-lead ECG alone (ECG-AI), and a model combining ECG-AI and CHARGE-AF (CH-AI). Two-year incident AF discrimination was assessed by the time-dependent area under the receiver-operating characteristic curve (AUROC) and average precision. AF screening effect was defined as the difference in 2-year incident AF diagnosis rate (per 100 person-years) in screening vs control across AF risk deciles. RESULTS: Of 30,630 VITAL-AF participants without prevalent AF, 16,937 had pretrial ECG and clinical data. Each score discriminated 2-year AF risk according to AUROC (CHARGE-AF: 0.711 [95% CI: 0.671-0.749]; ECG-AI: 0.784 [95% CI: 0.743-0.819]; CH-AI: 0.788 [95% CI: 0.754-0.824]) and average precision (0.0952 [95% CI: 0.0836-0.112]; 0.132 [95% CI: 0.113-0.157]; 0.133 [95% CI: 0.117-0.159]). An AF screening effect was observed in the top decile of CH-AI (AF diagnosis rate in screening 10.07/100 person-years [95% 8.28-11.87] vs 7.76 [95% 6.30-9.21] in control, P < 0.05), corresponding to a difference in AF diagnosis rate of 2.32/100 person-years (95% CI: 0.01-4.63) and number-needed-to-screen of 43 per year. CONCLUSIONS: Use of ECG-based AI and clinical factors identified individuals at particularly high risk for AF who may benefit from screening. Findings suggest a trade-off between increasing AF screening efficiency and decreasing population coverage (ie, restriction of the screening pool). Future studies are needed to determine whether a risk-based approach is optimal or whether consideration of additional clinical- and systems-level factors (eg, access, health care system engagement) can further refine AF screening strategies. (Screening for Atrial Fibrillation Among Older Patients in Primary Care Clinics [VITAL-AF]; NCT03515057).
No takes yet. Share an insight, caveat, or question.
Vedage et al. (2026) conducted an RCT in Atrial fibrillation screening (n=16,937). Single-lead ECG screening stratified by CH-AI (combined CHARGE-AF and ECG-AI) risk model vs. Usual care was evaluated on 2-year incident atrial fibrillation diagnosis rate (per 100 person-years) in the top decile of CH-AI predicted risk (Rate difference 2.32 per 100 person-years (NNT 43), 95% CI 0.01-4.63, p=<0.05). Single-lead ECG screening guided by the CH-AI model increased AF detection in the top risk decile by 2.32/100 person-years.
Synapse has enriched 10 related papers. Consider them for comparative context: