Key result
Preoperative supra-aortic false lumen communications linked to ~3x higher rate of dominant zone 4 false lumen.
Why the study?
The impact of false lumen communications within the supra-aortic vessels on aortic remodeling remained to be determined in patients undergoing open repair for acute DeBakey type I dissection.
Does the presence of preoperative supra-aortic vessel false lumen communications impact aortic remodeling at 1 year in patients undergoing acute DeBakey type I dissection repair with the AMDS hybrid prosthesis?
Cohort (n=93)
Open-label
Yes
Does the presence of preoperative supra-aortic vessel false lumen communications impact aortic remodeling at 1 year in patients undergoing acute DeBakey type I dissection repair with the AMDS hybrid prosthesis?
Absolute Event Rate: 58% vs 18%
p-value: p=<.05
Preoperative supra-aortic vessel false lumen communications are associated with adverse aortic remodeling and larger false lumens in the downstream aorta at 1 year after acute DeBakey type I dissection repair with the AMDS.
May warrant closer surveillance after DeBakey I repair; leaves open whether communications predict events or warrant intervention.
Objective:The PERSEVERE (ProspEctive, Single ARm, Multi-center Clinical InveStigation to EValuatE the Safety and Effectiveness of AMDS in the TREatment of Acute DeBakey Type I Dissection) Trial is a US investigational device exemption study designed to evaluate the Ascyrus Medical Dissection hybrid prosthesis in the open repair of patients with acute DeBakey type I dissection with preoperative malperfusion.We sought to determine the impact of false lumen (FL) communications within the supra-aortic vessels (SAV) on aortic remodeling by analyzing total aortic diameter (TAD), FL diameter, and true lumen (TL) diameter.Methods: Ninety-three patients were enrolled from July 2022 to November 2023.Anatomic measurements were made by a core laboratory using computed tomography angiogram (CTA).For this study, analysis was limited to zones 2, 3, and 4. TAD was assessed on first postoperative CTA and at 1-year postoperatively, and growth was defined as >1.0 cm.In addition, the percent of patients with FL diameter larger than TL diameter were compared on the basis of the presence or absence of any FL communications in the SAV.Results: Fifty-five patients had a preoperative, first postoperative CTA, and 1-year CTA scan and were included in the analysis.SAV FL communications were present on preoperative computed tomography scan in 35% (19/55) and absent in 65% (36/ 55).In those with SAV FL communications, TAD growth occurred in 0%, 5.3%, and 21.1% in zones 2, 3, and 4, respectively.In those without SAV FL communications, TAD growth occurred in 2.8%, 2.8%, and 8.3% in zones 2, 3 and 4, respectively; the difference did not reach statistical significance.The FL was larger than TL in significantly more patients in zones 3 and 4 in those with compared with those without SAV FL communications (zone 3, 53% vs 18%; zone 4, 58% vs 18%; P < .05). Conclusions:The presence of preoperative SAV FL communications has a significant impact on aortic remodeling at 1-year postoperatively.The presence of these communications is associated with a trend toward negative remodeling in zones 2, 3, and 4, in addition to a significantly larger FL compared with TL diameter, likely representing ongoing FL pressurization.Techniques to better identify SAV FL communications preoperatively may lead to a more tailored approach to operative management and more targeted postoperative surveillance in these patients.(JTCVS Structural and Endovascular 2025;8:100081) Innominate artery false lumen communication as demonstrated on preoperative CT.
No takes yet. Share an insight, caveat, or question.
Eudailey et al. (2025) conducted a cohort in Acute DeBakey type I aortic dissection with preoperative malperfusion (n=93). Presence of supra-aortic vessel false lumen communications vs. Absence of supra-aortic vessel false lumen communications was evaluated on False lumen diameter larger than true lumen diameter in zone 4 at 1 year (p=<.05). Preoperative supra-aortic vessel false lumen communications were associated with a significantly higher rate of false lumen diameter larger than true lumen diameter in zone 4 at 1 year compared to those without communications (58% vs 18%, P < .05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: