Key result
Candy-plug false lumen embolization during TEVAR yields 100% clinical success and increases true lumen diameter.
Why the study?
Retrograde false lumen perfusion after TEVAR can compromise positive remodeling and clinical outcomes, prompting evaluation of a false lumen thrombosis technique.
Does false lumen embolization using the candy-plug technique promote positive aortic remodeling in patients undergoing TEVAR for aortic dissection?
Observational (n=12)
No
Does false lumen embolization using the candy-plug technique promote positive aortic remodeling in patients undergoing TEVAR for aortic dissection?
False lumen embolization using a candy-plug during TEVAR is feasible and promotes positive aortic remodeling by significantly increasing true lumen diameter.
Feasibility suggested in small retrospective aortic dissection cohort; leaves open need for prospective outcome trials before practice change.
Background/Objectives: Retrograde false lumen perfusion after thoracic endovascular aortic repair (TEVAR) can compromise positive remodeling and clinical outcomes. The aim of this study is to describe the feasibility and outcomes of a false lumen thrombosis technique. Methods: A single-center, retrospective analysis of patients between January 2017 and January 2022 who underwent TEVAR in conjunction with false lumen embolization. Results: Twelve patients (83% type A, 17% type B; 33% with frank rupture; mean age 65 years; eleven men) underwent 13 false lumen embolization procedures with a 92% technical success rate and a 100% clinical success rate. Positive aortic remodeling was observed in all the patients. The maximum thoracic aortic diameter remained stable (p = 0.526) but the true lumen increased from 22 to 33 mm (p = 0.009) and the false lumen decreased from 41 to 20 mm (p = 0.076) after a median follow-up of 31 months. Conclusions: False lumen embolization using the candy-plug is safe and promotes positive aortic remodeling.
No takes yet. Share an insight, caveat, or question.
Halloum et al. (2025) conducted an observational in Aortic Dissection (n=12). False lumen embolization using the candy-plug during TEVAR was evaluated on Technical success, clinical success, and aortic remodeling. False lumen embolization using the candy-plug during TEVAR achieved 92% technical and 100% clinical success, increasing true lumen diameter from 22 to 33 mm (p=0.009).