Key result
Non-gated low-dose CT quantified epicardial adipose tissue volume with almost perfect concordance to ECG-gated cardiac CT.
Why the study?
Does non-gated thoracic low-radiation-dose CT provide reliable epicardial adipose tissue quantification compared to prospectively ECG-gated cardiac CT in asymptomatic smokers?
Cross-Sectional (n=60)
Blinded analysis
Does non-gated thoracic low-radiation-dose CT provide reliable epicardial adipose tissue quantification compared to prospectively ECG-gated cardiac CT in asymptomatic smokers?
Answers are grounded in this paper and cite their sources.
Non-gated low-dose chest CT can reliably quantify epicardial adipose tissue volume with comparable accuracy to dedicated ECG-gated cardiac CT, potentially allowing opportunistic cardiovascular risk assessment.
BACKGROUND: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. PURPOSE: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. MATERIAL AND METHODS: Sixty consecutive asymptomatic smokers (47 men; mean age 64 ± 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. RESULTS: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 ± 58.3 mL) with respect to ECG-gated CT (142.7 ± 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 ± 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. CONCLUSION: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols.
No takes yet. Share an insight, caveat, or question.
Simón-Yarza et al. (2012) conducted a cross-sectional in Asymptomatic smokers (n=60). Non-gated thoracic low-radiation-dose CT vs. Prospectively ECG-gated cardiac CT was evaluated on Epicardial adipose tissue (EAT) volume (CCC 0.99). Non-gated low-dose CT quantified epicardial adipose tissue volume with almost perfect concordance to ECG-gated cardiac CT.
Synapse has enriched 10 related papers. Consider them for comparative context: