Key result
AI-enabled smartwatch 2-lead ECG detects HFrEF with ~0.93 AUC.
Why the study?
The authors sought to develop and validate an artificial intelligence-enabled smartwatch ECG to detect heart failure-reduced ejection fraction.
Does an AI-enabled smartwatch 2-lead ECG accurately detect HFrEF in adult patients?
Cohort (n=177,071)
Yes
Does an AI-enabled smartwatch 2-lead ECG accurately detect HFrEF in adult patients?
An AI model can synthesize a 12-lead ECG from a 2-lead smartwatch ECG to accurately detect HFrEF, providing a potential non-invasive screening tool.
Answers are grounded in this paper and cite their sources.
May aid HFrEF screening via smartwatch ECG; hypothesis-generating and needs prospective validation before practice change.
BACKGROUND: We developed and validated an artificial intelligence (AI)-enabled smartwatch ECG to detect heart failure-reduced ejection fraction (HFrEF). METHODS: This was a cohort study involving two hospitals (A and B). We developed the AI in two steps. First, we developed an AI model (ECGT2T) to synthesize ten-lead ECG from the asynchronized 2-lead ECG (Lead I and II). ECGT2T is a deep learning model based on a generative adversarial network, which translates source ECGs to reference ECGs by learning styles of the reference ECGs. For this, we included adult patients aged ≥18 years from hospital A with at least one digitally stored 12-lead ECG. Second, we developed an AI model to detect HFrEF using a 10 s 12-lead ECG. The AI model was based on convolutional neural network. For this, we included adult patients who underwent ECG and echocardiography within 14 days. To validate the AI, we included adult patients from hospital B who underwent two-lead smartwatch ECG and echocardiography on the same day. The AI model generates a 10 s 12-lead ECG from a two-lead smartwatch ECG using ECGT2T and detects HFrEF using the generated 12-lead ECG. RESULTS: We included 137,673 patients with 458,745 ECGs and 38,643 patients with 88,900 ECGs from hospital A for developing the ECGT2T and HFrEF detection models, respectively. The area under the receiver operating characteristic curve of AI for detecting HFrEF using smartwatch ECG was 0.934 (95% confidence interval 0.913-0.955) with 755 patients from hospital B. The sensitivity, specificity, positive predictive value, and negative predictive value of AI were 0.897, 0.860, 0.258, and 0.994, respectively. CONCLUSIONS: An AI-enabled smartwatch 2-lead ECG could detect HFrEF with reasonable performance.
No takes yet. Share an insight, caveat, or question.
Kwon et al. (2022) conducted a cohort in Heart Failure-Reduced Ejection Fraction (HFrEF) (n=177,071). AI-enabled smartwatch 2-lead ECG was evaluated on Detection of HFrEF (AUC 0.934, 95% CI 0.913-0.955). An AI-enabled smartwatch 2-lead ECG detected heart failure with reduced ejection fraction with an area under the receiver operating characteristic curve of 0.934 (95% CI 0.913-0.955).