Why the study?
Does second-generation cryoballoon ablation achieve durable pulmonary vein isolation in patients with paroxysmal atrial fibrillation?
Does second-generation cryoballoon ablation achieve durable pulmonary vein isolation in patients with paroxysmal atrial fibrillation?
Second-generation cryoballoon ablation achieves a high rate of durable pulmonary vein isolation (91% of veins) at 3 months in patients with paroxysmal atrial fibrillation.
Answers are grounded in this paper and cite their sources.
May support cryoballoon PVI durability in paroxysmal AF; leaves open randomized confirmation of clinical benefit.
INTRODUCTION: Pulmonary vein (PV) reconnection remains the most important cause of AF recurrence after AF ablation. The second-generation cryoballoon catheter's ability to achieve durable PV isolation was assessed in a prospective nonrandomized clinical trial. METHODS AND RESULTS: PV isolation was performed by 4-minute ablations. Following verification of electrical isolation by a multielectrode mapping catheter, 1 additional lesion per PV was applied. Esophageal temperatures were monitored and all patients underwent postprocedure esophageal endoscopy. All patients underwent a second PV remapping procedure at ∼3 months to assess for PVI durability. Eighty-four (100%) veins were acutely isolated using only the 28 mm cryoballoon in 21 consecutive PAF patients with 2.2 ± 0.6 cryoapplications per vein, with the majority (83%) occurring after a single freeze. One patient presented with hematemesis and an esophageal ulceration that was treated conservatively; there were no episodes of esophageal fistula or phrenic nerve palsy. At 3.4 (2.9-4.1) months postablation, 68/75 veins (91%) remained electrically isolated; all PVs remained durably isolated in 79% of patients. Two patients accounted for 5 of 7 reconducting veins. The most common site for reconnection was the inferior aspect of the RIPV (3/7 reconnections). Reconnected veins had poorer occlusion at the index ablation procedure than veins that maintained chronic isolation (occlusion grade 2.9 ± 0.7 vs. 3.4 ± 0.7, P = 0.001). Clinical AF recurrence was detected in 2 patients (11%) at follow-up. CONCLUSIONS: The improved thermodynamic characteristics of the second-generation cryoballoon led to a high rate of both single-shot PVI and chronic lesion durability. This high rate of durable PV isolation is anticipated to translate to improved clinical outcome.
No takes yet. Share an insight, caveat, or question.
Reddy et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: