Key result
Magna Ease bioprostheses are linked to ~76% higher severe PPM rates in females versus males.
Why the study?
The study was conducted to evaluate the incidence of prosthesis-patient mismatch, hemodynamic performance, and clinical outcomes of the Carpentier-Edwards Magna Ease bioprosthesis in the aortic position across sexes and valve sizes.
Does sex or prosthesis size affect the incidence of prosthesis-patient mismatch and mortality in patients undergoing aortic valve replacement with the Carpentier-Edwards Magna Ease bioprosthesis?
Cohort (n=1,062)
Yes
Does sex or prosthesis size affect the incidence of prosthesis-patient mismatch and mortality in patients undergoing aortic valve replacement with the Carpentier-Edwards Magna Ease bioprosthesis?
Answers are grounded in this paper and cite their sources.
Female patients and those receiving smaller (19-21 mm) Carpentier-Edwards Magna Ease bioprostheses have significantly higher rates of severe prosthesis-patient mismatch, though this does not appear to impact short-term mortality.
Objective This study aims to assess the incidence of prosthesis–patient mismatch (PPM), the hemodynamic performance, as well as the clinical outcomes of the Carpentier-Edwards Magna Ease (CEME) bioprosthesis in the aortic position while addressing sex-based disparities and variations in valve size. Methods Between 2012 and 2022, 1062 patients underwent an AVR with a CEME bioprosthesis in two high-volume cardiac surgery centers. Predicted PPM was assessed using manufacturer and Lancellotti et al. chart values, alongside measured values. Echocardiographic measurements were evaluated over a 5-year period. Results Predicted PPM based on the manufacturer chart was noted in 2.1% of women and 0.28% of men ( P < .001). When employing definitions by Lancellotti et al., PPM was detected in 45% of females and 18% of males ( P < .001). Notable differences were observed in terms of severe measured PPM in favor of male patients (F: 30%, M: 17%, P < .01). Regarding prosthesis sizes, the comparison of PPM from the manufacturer's chart with Lancellotti et al. values revealed significant disparities: 2% versus 58% in the 19 to 21 mm group, 0.27% versus 13% in the 23 mm group, and 0% versus 1.1% in the ≥25 mm valve sizes ( P < .001). Measured severe PPM was encountered in 30% of patients with 19 to 21 mm prosthesis, 20% in the 23 mm group and 12% in the >25 mm prosthesis. Despite these differences, mortality rates remained comparable across sexes and valve sizes. Conclusion Female patients and those with 19 to 21 mm prostheses experience more severe PPM compared to men or individuals with larger valves. In this contemporary cohort, PPM does not impact short-term mortality.
No takes yet. Share an insight, caveat, or question.
Calin et al. (2025) conducted a cohort in Aortic valve replacement (n=1,062). Carpentier-Edwards Magna Ease (CEME) bioprosthesis vs. Male patients and larger prosthesis sizes was evaluated on Severe measured prosthesis-patient mismatch (PPM) (p=<0.01). Female patients receiving the Carpentier-Edwards Magna Ease bioprosthesis had significantly higher rates of severe measured prosthesis-patient mismatch than males (30% vs 17%, P<0.01).
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: