Key result
Biological aortic valve prostheses had similar long-term mortality to mechanical valves, but higher risks of reoperation and lower risks of stroke and bleeding.
Why the study?
Does a biological aortic valve prosthesis compared to a mechanical prosthesis improve long-term clinical outcomes in older patients undergoing aortic valve replacement?
Cohort (n=39,199)
Yes
Does a biological aortic valve prosthesis compared to a mechanical prosthesis improve long-term clinical outcomes in older patients undergoing aortic valve replacement?
In older patients undergoing aortic valve replacement, biological and mechanical valves offer similar long-term survival, but biological valves carry higher risks of reoperation and endocarditis and lower risks of stroke and bleeding.
Answers are grounded in this paper and cite their sources.
Biological valves link to similar mortality with fewer strokes/bleeds but more reoperations in older AVR patients; extends observational data without supporting practice changes.
BACKGROUND: There is a paucity of long-term data comparing biological versus mechanical aortic valve prostheses in older individuals. METHODS AND RESULTS: We performed follow-up of patients aged 65 to 80 years undergoing aortic valve replacement with a biological (n=24 410) or mechanical (n=14 789) prosthesis from 1991 to 1999 at 605 centers within the Society of Thoracic Surgeons Adult Cardiac Surgery Database using Medicare inpatient claims (mean, 12.6 years; maximum, 17 years; minimum, 8 years), and outcomes were compared by propensity methods. Among Medicare-linked patients undergoing aortic valve replacement (mean age, 73 years), both reoperation (4.0%) and endocarditis (1.9%) were uncommon to 12 years; however, the risk for other adverse outcomes was high, including death (66.5%), stroke (14.1%), and bleeding (17.9%). Compared with those receiving a mechanical valve, patients given a bioprosthesis had a similar adjusted risk for death (hazard ratio, 1.04; 95% confidence interval, 1.01-1.07), higher risks for reoperation (hazard ratio, 2.55; 95% confidence interval, 2.14-3.03) and endocarditis (hazard ratio, 1.60; 95% confidence interval, 1.31-1.94), and lower risks for stroke (hazard ratio, 0.87; 95% confidence interval, 0.82-0.93) and bleeding (hazard ratio, 0.66; 95% confidence interval, 0.62-0.70). Although these results were generally consistent among patient subgroups, bioprosthesis patients aged 65 to 69 years had a substantially elevated 12-year absolute risk of reoperation (10.5%). CONCLUSIONS: Among patients undergoing aortic valve replacement, long-term mortality rates were similar for those who received bioprosthetic versus mechanical valves. Bioprostheses were associated with a higher long-term risk of reoperation and endocarditis but a lower risk of stroke and hemorrhage. These risks varied as a function of a patient's age and comorbidities.
No takes yet. Share an insight, caveat, or question.
Brennan et al. (2013) conducted a cohort in Aortic valve replacement (n=39,199). Biological aortic valve prosthesis vs. Mechanical aortic valve prosthesis was evaluated on Death (HR 1.04, 95% CI 1.01-1.07). Biological aortic valve prostheses had similar long-term mortality to mechanical valves, but higher risks of reoperation and lower risks of stroke and bleeding.
Synapse has enriched 10 related papers. Consider them for comparative context: