Key result
Higher clinical frailty predicts ~100% higher death and HF hospitalization risk in CIED patients.
Why the study?
Indications for cardiac implantable electric device implantation have not been clearly defined in patients with poor ability to perform activities of daily living, such as those with a high Clinical Frailty Score.
Does the Clinical Frailty Score predict long-term mortality and heart failure hospitalization in patients undergoing initial cardiac implantable electric device implantation?
Cohort (n=323)
No
Does the Clinical Frailty Score predict long-term mortality and heart failure hospitalization in patients undergoing initial cardiac implantable electric device implantation?
The Clinical Frailty Score is an independent predictor of mortality and heart failure hospitalization in patients receiving a CIED, highlighting its utility in risk stratification.
Answers are grounded in this paper and cite their sources.
May inform risk stratification in CIED recipients; leaves open whether frailty modification improves outcomes.
BACKGROUND: Although patients with poor ability to perform activities of daily living, such as those with high Clinical Frailty Score (CFS), will often receive a cardiac implantable electric device (CIED), the indications for implantation in these patients have not been clearly defined. We investigated the association between CFS and prognosis in patients with a CIED. METHODS AND RESULTS: We retrospectively enrolled 323 consecutive patients who underwent initial device implantation (age, 77 (70-83) years; male, 181 [56%] patients; high-voltage device, 49 [15%] patients), and the CFS was retrospectively estimated. Primary outcome was all-cause death, and the secondary outcome was hospitalization due to heart failure (HF). Median CFS was 4 (3-5) points. During 2 years' follow-up, all-cause death occurred in 32 patients (10%). Freedom from all-cause death was significantly lower in patients with a high CFS than in those with a low score (1-2 points: 100%, 3-4 points: 92.9%, 5-9 points: 77.3%, P<0.01). After adjustment for age and sex, the CFS was an independent predictor of the primary outcome (hazard ratio [HR] 2.0, 95% confidence interval [CI] 1.6-2.5, P<0.01), and of the secondary outcome (HR 1.6 [95% CI 1.2-2.0], P<0.01). CONCLUSIONS: The CFS is an independent predictor of both death and hospitalization due to HF in patients with a CIED.
No takes yet. Share an insight, caveat, or question.
Matsuda et al. (2021) conducted a cohort in Patients undergoing cardiac implantable electric device (CIED) implantation (n=323). High Clinical Frailty Score (CFS) vs. Low Clinical Frailty Score was evaluated on All-cause death (HR 2.0, 95% CI 1.6-2.5, p=<0.01). A higher Clinical Frailty Score independently predicted an increased risk of all-cause death and hospitalization due to heart failure in patients receiving a cardiac implantable electric device.
Synapse has enriched 10 related papers. Consider them for comparative context: