Why the study?
Does non-evidence-based ICD implantation increase in-hospital mortality and complications compared to evidence-based ICD implantation in patients receiving primary prevention ICDs?
Does non-evidence-based ICD implantation increase in-hospital mortality and complications compared to evidence-based ICD implantation in patients receiving primary prevention ICDs?
Answers are grounded in this paper and cite their sources.
Nearly one-quarter of primary prevention ICD implants in the US do not meet evidence-based criteria and are associated with significantly higher in-hospital mortality and complications.
CONTEXT: Practice guidelines do not recommend use of an implantable cardioverter-defibrillator (ICD) for primary prevention in patients recovering from a myocardial infarction or coronary artery bypass graft surgery and those with severe heart failure symptoms or a recent diagnosis of heart failure. OBJECTIVE: To determine the number, characteristics, and in-hospital outcomes of patients who receive a non-evidence-based ICD and examine the distribution of these implants by site, physician specialty, and year of procedure. DESIGN, SETTING, AND PATIENTS: Retrospective cohort study of cases submitted to the National Cardiovascular Data Registry-ICD Registry between January 1, 2006, and June 30, 2009. MAIN OUTCOME MEASURE: In-hospital outcomes. RESULTS: Of 111,707 patients, 25,145 received non-evidence-based ICD implants (22.5%). Patients who received a non-evidence-based ICD compared with those who received an evidence-based ICD had a significantly higher risk of in-hospital death (0.57% [95% confidence interval {CI}, 0.48%-0.66%] vs 0.18% [95% CI, 0.15%-0.20%]; P <.001) and any postprocedure complication (3.23% [95% CI, 3.01%-3.45%] vs 2.41% [95% CI, 2.31%-2.51%]; P <.001). There was substantial variation in non-evidence-based ICDs by site. The rate of non-evidence-based ICD implants was significantly lower for electrophysiologists (20.8%; 95% CI, 20.5%-21.1%) than nonelectrophysiologists (24.8% [95% CI, 24.2%-25.3%] for nonelectrophysiologist cardiologists; 36.1% [95% CI, 34.3%-38.0%] for thoracic surgeons; and 24.9% [95% CI, 23.8%-25.9%] for other specialties) (P<.001 for all comparisons). There was no clear decrease in the rate of non-evidence-based ICDs over time (24.5% [6908/28,233] in 2006, 21.8% [7395/33,965] in 2007, 22.0% [7245/32,960] in 2008, and 21.7% [3597/16,549] in 2009; P <.001 for trend from 2006-2009 and P = .94 for trend from 2007-2009). CONCLUSION: Among patients with ICD implants in this registry, 22.5% did not meet evidence-based criteria for implantation.
No takes yet. Share an insight, caveat, or question.
Sana M. Al‐Khatib (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: