Key result
Multilayer perceptron model estimates carotid-to-femoral pulse wave velocity from distal PPG waveforms with ~98% accuracy.
Why the study?
Carotid-to-femoral pulse wave velocity is the gold standard for measuring arterial stiffness, but its clinical measurement is very intrusive and complicated.
Answers are grounded in this paper and cite their sources.
A multilayer perceptron-based model can accurately estimate carotid-to-femoral pulse wave velocity from distal PPG waveforms in an in-silico setting, offering a potential non-invasive method to assess arterial stiffness.
Cardiovascular diseases (CVDs) are the primary cause of death in the world. The development of easy-to-use and non-invasive monitoring CVDs’ diagnosis methods is crucial. Among the key parameters in the cardiovascular system is arterial stiffness. An increase in arterial stiffness is considered a primary risk factor for CVDs. Although arterial stiffness can be assessed non-invasively by measuring the carotid-to-femoral pulse wave velocity (cf−PWV), which is considered as a gold standard for arterial stiffness measurement, the clinical process of assessing this parameter is very intrusive and complicated. This paper investigated the potential of estimating (cf−PWV) from distal photoplethysmogram (PPG) waveforms using regression technique based on a multilayer perceptron. Functionally, PPG offers a simple, reliable, low-cost technique to measure blood volume change and hence assess cardiovascular function. In this work, we identify and select features from the timing fiducial points-based PPG, its first, second, and third derivative waveforms. The in-silico validation shows promising results and satisfactory accuracy. It demonstrates good estimation performances with an R 2 (correlation coefficient) around 0.95 and MAPE (mean absolute percentage error) less than 2.22% based on features extracted from PPG at the brachial artery level, an R 2 around 0.98 and MAPE less than 1.71% based on features extracted from PPG at the radial artery level and R 2 around 0.97 and MAPE less than 1.88% based on features extracted from PPG at the digital artery level.
No takes yet. Share an insight, caveat, or question.
Bahloul et al. (2021) studied Arterial stiffness. Multilayer perceptron-based cf-PWV estimation using PPG signal was evaluated on Estimation accuracy of carotid-to-femoral pulse wave velocity (R2 and MAPE). A multilayer perceptron model estimated carotid-to-femoral pulse wave velocity from distal PPG waveforms with high accuracy, achieving an R2 of ~0.98 and MAPE <1.71% at the radial artery level.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: