Why the study?
Does the presence of S. aureus aetiology and cold closed pocket (CCP) pattern predict 1-year mortality in patients undergoing transvenous lead extraction for CIED infections?
Cohort (n=292)
Yes
Does the presence of S. aureus aetiology and cold closed pocket (CCP) pattern predict 1-year mortality in patients undergoing transvenous lead extraction for CIED infections?
The BOP2D score, incorporating S. aureus aetiology and cold closed pocket infection pattern, effectively stratifies 1-year mortality risk in patients undergoing transvenous lead extraction for CIED infections.
Answers are grounded in this paper and cite their sources.
May aid mortality risk stratification in CIED extraction patients; hypothesis-generating and requires prospective validation before practice change.
D score presented a 0.807 AUC (95%CI 0.703-0.910, p < 0.001) and a good predictive value (OR 2.355, 95%CI 1.754-3.162; p < 0.001), and was associated with a progressive increase in mortality with a score > 2. The score validation with the registry from the Padua University (135 patients) retrieved a C-statistic of 0.746 (95%CI 0.613-0.879; p = 0.002). Both CCP and S. aureus were confirmed as risk factors for mortality in CIEDI patients. This study supports the hypothesis that the infectious process may occur through different mechanisms associated with different infection patterns, and high-risk patients should be considered for specific and aggressive approaches.
No takes yet. Share an insight, caveat, or question.
Massaro et al. (2024) conducted a cohort in Cardiac implantable electronic device infections (CIEDI) (n=292). BOP2D score (S. aureus, Cold Closed Pocket, renal impairment, left ventricular dysfunction) was evaluated on 1-year mortality (OR 2.355, 95% CI 1.754-3.162, p=<0.001).