Key result
Cardiac troponin I and high-sensitive troponin T detect primary myocardial damage in horses with ~91% sensitivity.
Why the study?
Are cTnI and hs-cTnT assays useful for the detection of myocardial damage in horses?
Observational (n=99)
Yes
Are cTnI and hs-cTnT assays useful for the detection of myocardial damage in horses?
Both cTnI and hs-cTnT assays are useful for detecting myocardial damage in horses, though they have large quantitative differences and require specific cut-offs.
Answers are grounded in this paper and cite their sources.
Supports troponin testing in equine patients; leaves open optimal cutoffs and validation in prospective clinical cohorts.
Background Different cardiac troponin I (cTnI) assays give different results. Only 1 manufacturer has marketed troponin T (cTnT) assays. Therefore, cTnT often is preferred for detection of myocardial infarction in human patients. Studies of cTnT in horses are limited. Objectives To compare a cTnI and a high-sensitive cTnT assay (hs-cTnT) in horses. Animals Cardiac troponin I and cTnT were determined in 35 healthy horses (group 1), 23 horses suspected to have primary myocardial damage (group 2a), and 41 horses with secondary myocardial damage caused by structural heart disease (group 2b). Methods All cTnI samples were analyzed at laboratory A (limit of detection [LOD]: 0.03 ng/mL), whereas cTnT samples were analyzed at 2 laboratories with the same hs-cTnT assay (laboratory B, LOD: 10.0 pg/mL; laboratory C, LOD: 4.0 pg/mL). Results The median cTnI concentration in group 2a (0.90 ng/mL; range, 0.03–58.27 ng/mL) was significantly higher (P < .001) than in group 1 (0.03 ng/mL; range, 0.03–0.09 ng/mL) or group 2b (0.05 ng/mL; range, 0.03–30.92 ng/mL), and the optimal cut-off for detection of primary myocardial damage was 0.095 ng/mL (sensitivity: 90.5%, specificity: 100%). Using an LOD of 10.0 pg/mL for all cTnT samples, a cut-off value of 10.5 pg/mL was found, but sensitivity was low (42.9%). When only samples analyzed at laboratory C (n = 58) were included, a cut-off of 6.6 pg/mL was found (sensitivity: 81%, specificity: 100%). Conclusions and Clinical Importance Despite large quantitative differences, cTnI and cTnT are both useful for detection of myocardial damage in horses.
No takes yet. Share an insight, caveat, or question.
Vekens et al. (2015) conducted an observational in Myocardial damage (n=99). Cardiac troponin I (cTnI) assay vs. High-sensitive cardiac troponin T (hs-cTnT) assay was evaluated on Detection of primary myocardial damage (p=<.001). Cardiac troponin I and high-sensitive troponin T assays are both useful for detecting primary myocardial damage in horses, with sensitivities of 90.5% and up to 81%, respectively.
Synapse has enriched 10 related papers. Consider them for comparative context: