Syncope in a patient with hypertrophic cardiomyopathy was attributed to a primary haemodynamic mechanism, such as reduced left ventricular volume, rather than an arrhythmia.
This case report suggests that syncope in hypertrophic cardiomyopathy can be driven by primary haemodynamic mechanisms, such as a reduction in left ventricular volume, rather than arrhythmias.
Answers are grounded in this paper and cite their sources.
May prompt hemodynamic evaluation in HCM syncope; hypothesis-generating and leaves open arrhythmia prevalence pending larger studies.
A patient with hypertrophic cardiomyopathy, syncope, and frequent ventricular tachycardia was monitored during a syncopal episode. An unrecordable blood pressure and the loss of a left ventricular outflow tract murmur without evidence of arrhythmia suggested a primary haemodynamic mechanism such as reduction in left ventricular volume.
No takes yet. Share an insight, caveat, or question.
McKenna et al. (1982) studied this question. Syncope in a patient with hypertrophic cardiomyopathy was attributed to a primary haemodynamic mechanism, such as reduced left ventricular volume, rather than an arrhythmia.