Key result
Bernoulli formulation overestimates transvalvular peak pressure drops by ~54% compared to flow field computations.
Why the study?
Does the Bernoulli principle accurately estimate peak pressure drop at the aortic valve compared to Navier-Stokes equations in subjects undergoing cardiovascular magnetic resonance?
Observational (n=32)
Does the Bernoulli principle accurately estimate peak pressure drop at the aortic valve compared to Navier-Stokes equations in subjects undergoing cardiovascular magnetic resonance?
The standard Bernoulli formulation significantly overestimates transvalvular peak pressure drops by assuming a single streamline, highlighting the need for a corrected formulation that accounts for cross-sectional flow profiles.
Answers are grounded in this paper and cite their sources.
Caution advised for Bernoulli-derived gradients on CMR; hypothesis-generating for flow-profile-adjusted alternatives.
BACKGROUND: Transvalvular peak pressure drops are routinely assessed noninvasively by echocardiography using the Bernoulli principle. However, the Bernoulli principle relies on several approximations that may not be appropriate, including that the majority of the pressure drop is because of the spatial acceleration of the blood flow, and the ejection jet is a single streamline (single peak velocity value). METHODS AND RESULTS: We assessed the accuracy of the Bernoulli principle to estimate the peak pressure drop at the aortic valve using 3-dimensional cardiovascular magnetic resonance flow data in 32 subjects. Reference pressure drops were computed from the flow field, accounting for the principles of physics (ie, the Navier-Stokes equations). Analysis of the pressure components confirmed that the spatial acceleration of the blood jet through the valve is most significant (accounting for 99% of the total drop in stenotic subjects). However, the Bernoulli formulation demonstrated a consistent overestimation of the transvalvular pressure (average of 54%, range 5%-136%) resulting from the use of a single peak velocity value, which neglects the velocity distribution across the aortic valve plane. This assumption was a source of uncontrolled variability. CONCLUSIONS: The application of the Bernoulli formulation results in a clinically significant overestimation of peak pressure drops because of approximation of blood flow as a single streamline. A corrected formulation that accounts for the cross-sectional profile of the blood flow is proposed and adapted to both cardiovascular magnetic resonance and echocardiographic data.
No takes yet. Share an insight, caveat, or question.
Donati et al. (2017) conducted an observational in Aortic valve pressure drop assessment (n=32). Bernoulli principle vs. Navier-Stokes equations (reference pressure drops) was evaluated on Accuracy of the Bernoulli principle to estimate peak pressure drop at the aortic valve (54% average overestimation, 95% CI range 5%-136%). The Bernoulli formulation consistently overestimated transvalvular peak pressure drops by an average of 54% (range 5%-136%) compared to reference pressure drops computed from the flow field.