Why the study?
BiV-CRT is ineffective in approximately one-third of patients, while conduction system pacing may achieve greater synchronization.
Does conduction system pacing (His-CRT or LBB-CRT) improve echocardiographic and clinical outcomes compared to biventricular pacing in patients with reduced LVEF?
Does conduction system pacing (His-CRT or LBB-CRT) improve echocardiographic and clinical outcomes compared to biventricular pacing in patients with reduced LVEF?
Conduction system pacing (His-CRT and LBB-CRT) is associated with greater improvements in QRS duration, LVEF, and clinical response compared to traditional biventricular pacing in patients with reduced LVEF.
Answers are grounded in this paper and cite their sources.
Supports conduction system pacing over BiV-CRT in reduced LVEF; extends prior evidence with mortality reduction.
INTRODUCTION: Cardiac resynchronization therapy (CRT) with biventricular pacing (BiV-CRT) is ineffective in approximately one-third of patients. CRT with Conduction system pacing (CSP-CRT) may achieve greater synchronization. We aimed to assess the effectiveness of CRT with His pacing (His-CRT) or left bundle branch pacing (LBB-CRT) in lieu of biventricular CRT. METHODS AND RESULTS: The PubMed, Embase, Web of Science, Scopus, and the Cochrane Library were systematically searched until August 19, 2023, for original studies including patients with reduced left ventricular ejection fraction (LVEF) who received His- or LBB-CRT, that reported either CSP-CRT success, LVEF, QRS duration (QRSd), or New York Heart Association (NYHA) classification. Effect measures were compared with frequentist network meta-analysis. Thirty-seven publications, including 20 comparative studies, were included. Success rates were 73.5% (95% CI: 61.2-83.0) for His-CRT and 91.5% (95% CI: 88.0-94.1) for LBB-CRT. Compared to BiV-CRT, greater improvements were observed for LVEF (mean difference [MD] for His-CRT +3.4%; 95% CI [1.0; 5.7], and LBB-CRT: +4.4%; [2.5; 6.2]), LV end-systolic volume (His-CRT:17.2mL [29.7; 4.8]; LBB-CRT:15.3mL [28.3; 2.2]), QRSd (His-CRT: -17.1ms [-25.0; -9.2]; LBB-CRT: -17.4ms [-23.2; -11.6]), and NYHA (Standardized MD [SMD]: His-CRT:0.4 [0.8; 0.1]; LBB-CRT:0.4 [-0.7; -0.2]). Pacing thresholds at baseline and follow-up were significantly lower with LBB-CRT versus both His-CRT and BiV-CRT. CSP-CRT was associated with reduced mortality (R = 0.75 [0.61-0.91]) and hospitalizations risk (RR = 0.63 [0.42-0.96]). CONCLUSION: This study found that CSP-CRT is associated with greater improvements in QRSd, echocardiographic, and clinical response. LBB-CRT was associated with lower pacing thresholds. Future randomized trials are needed to determine CSP-CRT efficacy.
No takes yet. Share an insight, caveat, or question.
Tavolinejad et al. (2023) studied this question.