Key result
Conduction system pacing did not significantly improve left ventricular ejection fraction compared with biventricular pacing for CRT (MD +2.40%, 95% CI -0.49 to 5.29, p=0.091).
Why the study?
Conduction system pacing is an emerging alternative to biventricular pacing for cardiac resynchronization therapy, but divergent results from recent randomized controlled trials have created uncertainty about their comparative effectiveness.
Does conduction system pacing improve left ventricular ejection fraction and clinical outcomes compared with biventricular pacing in adults with heart failure and a cardiac resynchronization therapy indication?
Meta-Analysis (n=799)
Open-label
Parallel-group RCTs
Yes
Does conduction system pacing improve left ventricular ejection fraction and clinical outcomes compared with biventricular pacing in adults with heart failure and a cardiac resynchronization therapy indication?
Mean Difference: 2.4 (95% CI -0.49–5.29)
p-value: p=0.091
In this meta-analysis of 8 parallel-group RCTs (n=799), conduction system pacing showed no statistically significant difference in LVEF improvement or clinical outcomes compared with biventricular pacing for CRT overall, although exploratory subgroup analyses suggested incremental LVEF benefit in LBBB patients receiving confirmed LBBAP/LBBP.
Background Conduction system pacing (CSP) is an emerging alternative to biventricular pacing (BVP) for cardiac resynchronization therapy (CRT). Recent randomized controlled trials (RCTs) have yielded divergent results, creating uncertainty about the comparative effectiveness. Methods We performed a systematic review and meta‐analysis of RCTs comparing CSP with BVP for CRT, searching PubMed, Embase, and CENTRAL through May 2026 (updating a prior review). The primary outcome was change in left ventricular ejection fraction (ΔLVEF), analyzed with random‐effects models and prediction intervals. Results Eight parallel‐group RCTs including 799 patients (396 CSP, 403 BVP) were included. Pooled ΔLVEF did not differ significantly (MD +2.40%, 95% CI −0.49 to 5.29, p = 0.091; I 2 = 75%). CSP showed a non‐significant trend toward shorter paced QRS (MD −7.6 ms, p = 0.14) and improved NYHA class (SMD −0.33, p = 0.12). Heart failure hospitalization (RR 0.69), mortality (RR 1.17), complications (RR 0.84), and procedure time did not differ. The four trials enrolling exclusively LBBB patients favored CSP (MD +5.00%, 95% CI 3.01 to 6.98, p = 0.004; I 2 = 0%), consistent in the three using confirmed LBBAP/LBBP (MD +5.37%, 95% CI 3.23 to 7.52, p = 0.008; I 2 = 0%). Conclusions In this analysis of randomized trials of CRT, no statistically significant difference was observed between CSP and BVP for any outcome. Because no non‐inferiority margin was prespecified and the clinical‐event analyses were underpowered, these findings should not be interpreted as establishing equivalence or comparable safety. Exploratory analyses suggest that patients with LBBB undergoing LBBAP/LBBP may derive incremental benefit, warranting confirmation in adequately powered trials.
No takes yet. Share an insight, caveat, or question.
Singireddy et al. (2026) conducted a meta-analysis in Heart failure with reduced ejection fraction and conduction delay requiring cardiac resynchronization therapy (n=799). Conduction system pacing (CSP) vs. Biventricular pacing (BVP) was evaluated on Change in left ventricular ejection fraction (ΔLVEF, %) (MD +2.40%, 95% CI -0.49 to 5.29, p=0.091). Conduction system pacing did not significantly improve left ventricular ejection fraction compared with biventricular pacing for CRT (MD +2.40%, 95% CI -0.49 to 5.29, p=0.091).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: