Why the study?
The high rate of intraoperative and postoperative LV lead dislocation limits CRT application, prompting evaluation of the long-term safety and effectiveness of the loop technique for repeated intraoperative dislocations.
Does the loop technique provide comparable safety and effectiveness to traditional operation in heart failure patients undergoing CRT?
Does the loop technique provide comparable safety and effectiveness to traditional operation in heart failure patients undergoing CRT?
The loop technique appears to be a safe and effective alternative for LV lead placement in HF patients experiencing repeated intraoperative dislocations during CRT.
Answers are grounded in this paper and cite their sources.
Loop technique associated with similar mortality and no added complications in CRT; leaves open its role pending randomized confirmation.
Objectives Cardiac resynchronization therapy (CRT) is a well-established method that improves the clinical symptoms and long-term prognosis of specific heart failure (HF) patients by restoring systolic synchronicity and enhancing myocardial function. However, the high rate of intraoperative and postoperative left ventricular (LV) lead dislocation limits its application to a great extent. The aim of this study was to demonstrate the long-term safety and effectiveness of a new approach named the loop technique for patients who experience repeated intraoperative transvenous LV lead dislocations during CRT. Methods The current study was a single-centre, prospective, nonrandomized controlled trial. Forty-four HF patients who underwent CRT were included. All patients were followed to death or 3 years. Results Among 44 HF patients, 36 underwent the traditional operation, and 8 underwent the loop technique due to repeated intraoperative LV lead dislocations. Intergroup comparison revealed no significant differences between the two groups with respect to most preoperative indices, intraoperative pacing and sensing parameters. At the end of the 3-year follow-up, 4 (11.1%) patients in the traditional operation group and 2 (25.0%) patients in the loop technique group had died. There was no significant difference in the mortality rate ( P = 0.30). No complications related to this new technique were observed, such as intracoronary thrombosis, infection or dislocation. Intergroup comparison showed no significant difference in the New York Heart Association (NYHA) class, echocardiography indices, N-terminal pro brain natriuretic peptide (NT-proBNP) level or pacemaker programming parameters. Conclusions The loop technique is a safe and effective alternative method for patients who experience repeated intraoperative transvenous LV lead dislocations during CRT.
No takes yet. Share an insight, caveat, or question.
Dong et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: