Key result
Ropivacaine-sufentanil test dose detects intrathecal injection, causing sensory blockade in ~100% of intrathecal placements.
Why the study?
Traditional epidural test doses carry potential risks of severe adverse effects if accidentally injected into the subarachnoid space in obstetric patients.
Does ropivacaine 5 mg with sufentanil 2.5 μg effectively and safely detect intrathecal injection in parturients demanding epidural labor analgesia?
RCT
randomized
Does ropivacaine 5 mg with sufentanil 2.5 μg effectively and safely detect intrathecal injection in parturients demanding epidural labor analgesia?
Absolute Event Rate: 100% vs 2.33%
p-value: p=< 0.0001
Ropivacaine 5 mg with sufentanil 2.5 μg is an effective and safe test dose for detecting accidental intrathecal injection during epidural labor analgesia.
Supports adoption of this ropivacaine-sufentanil test dose in labor epidurals; confirms reliable intrathecal detection in RCT.
Objectives: Traditional epidural test dose is somewhat unsuited in obstetrics because of potential risk of severe adverse effects when it is accidentally injected into the subarachnoid space. Some hospitals use a proportion of the total dose of epidural labor analgesia as a test dose. The aim of our study was to assess the effectiveness and safety of ropivacaine 5 mg with sufentanil 2.5 μg to detect intrathecal injection. Methods: This prospective randomized study enrolled parturients who had the demand for epidural labor analgesia and randomly divided them into two groups. Then, 5 mL of 0.1% ropivacaine with sufentanil 2.5 μg was injected into the epidural space or the subarachnoid space in the epidural (EP) group and the intrathecal (IT) group, respectively. The ability to detect intrathecal injection and side effects were assessed to work out the effectiveness and safety. Results: For spinal injection, the sensitivity and the specificity of the symptoms of either warmth or numbness or both assessed at 3 min were both 100%, and the observed negative predictive value (NPV) and positive predictive value (PPV) were 100%. All parturients in the IT group and 2.33% of parturients in the EP group had sensory blockade to cold or pinprick (p < 0.0001). A total of 77.55% (38 of 49) of parturients in the IT group were found to have a motor block. A 10 min assessment showed the median cephalad cold and pin levels were T8 and T10, respectively, and the median Bromage score was 4 in the IT group. Incidences of adverse effects in both groups were low. Conclusions: Ropivacaine 5 mg with sufentanil 2.5 μg is effective and safe to detect intrathecal injection as an epidural test dose in obstetric patients.
No takes yet. Share an insight, caveat, or question.
Li et al. (2022) conducted an RCT in Obstetric patients requiring epidural labor analgesia. Ropivacaine with sufentanil vs. Epidural injection was evaluated on Sensory blockade to cold or pinprick (p=< 0.0001). A test dose of ropivacaine 5 mg with sufentanil 2.5 μg effectively detected intrathecal injection, causing sensory blockade in 100% of intrathecal vs 2.33% of epidural injections (p<0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: