Key result
Automated office BP improves data reliability over conventional methods despite high costs and limited data.
Why the study?
The clinical equivalence and widespread utility of automated office blood pressure compared with conventional office and ambulatory blood pressure measurements remain open questions.
Does automated office blood pressure (AOBP) measurement improve the diagnosis and control of arterial hypertension compared to conventional office blood pressure measurement?
Does automated office blood pressure (AOBP) measurement improve the diagnosis and control of arterial hypertension compared to conventional office blood pressure measurement?
Answers are grounded in this paper and cite their sources.
Automated office blood pressure measurement offers standardized and reliable readings comparable to 24-hour monitoring, but cost and data limitations currently hinder its widespread adoption.
Some national guidelines since 2017 considered the most common method for diagnosing and controlling hypertension (HTN) (office blood pressure (OBP) measurement) as screening only. Automated OBP (AOBP) measurement claims to be a unique method by obtaining a standardized result, even in primary health care. AOBP improves the reliability of data by reducing the influence of various errors on result. However, although the level of AOBP is on average lower than similar OBP in clinical and research practice and is comparable to the mean 24-hour BP monitoring, at present, all international guidelines emphasize the mandatory use of ambulatory BP measurements for diagnostic purposes. Whether the results of AOBP and the reference level ≥130/80 mm Hg are equivalent with the same OBP level, the use of which is associated with an increase in the prevalence of hypertension and insufficient control of antihypertensive therapy, is a question for research. Compared with conventional OBP, the use of AOBP in conjunction with outpatient measurement leads to a reduction in the proportion and timing of initiation of treatment in patients with masked HTN, whose cardiovascular risk is similar to that of patients with stable HTN. However, the widespread implementation of AOBP is hindered by the high cost and lack of accumulated data. The review analyzes in detail the limitations and advantages of various types of BP measurement, as well as the potential of using AOBP in modern clinical and research practice.
No takes yet. Share an insight, caveat, or question.
Платонова et al. (2022) conducted a review in Arterial hypertension. Automated office blood pressure (AOBP) measurement vs. Conventional office blood pressure (OBP) measurement was evaluated. Automated office blood pressure measurement improves data reliability over conventional methods, though its widespread implementation is hindered by high costs and lack of accumulated data.
Synapse has enriched 10 related papers. Consider them for comparative context: