Why the study?
Differences in the predictability of PVC ablation success among EIA, ⊾LAT Bi-Uni, LAT Bi, and unipolar QS or Q pattern morphology remained unclear.
Do EIA 10ms and ⊿LAT Bi-Uni improve the prediction of ablation success compared to LAT Bi and unipolar morphology in patients with PVCs undergoing catheter ablation?
Do EIA 10ms and ⊿LAT Bi-Uni improve the prediction of ablation success compared to LAT Bi and unipolar morphology in patients with PVCs undergoing catheter ablation?
EIA 10ms and ⊿LAT Bi-Uni are more accurate predictors of ablation success for PVCs on mapped cardiac surfaces than LAT Bi and unipolar morphology.
May enhance PVC ablation prediction on mapped surfaces; extends mapping criteria but leaves open prospective validation.
Introduction Differences in predictability of ablation success for premature ventricular contractions (PVCs) between earliest isochronal map area (EIA), local activation time (LAT) differences on unipolar and bipolar electrograms (⊿LAT Bi‐Uni ), LAT prematurity on bipolar electrograms (LAT Bi ), and unipolar morphology of QS or Q pattern remain unclear. We verified multiple statistical predictabilities of those indicators of ablation success on mapped cardiac surface. Methods Thirty‐five patients with multiple PVCs underwent catheter ablation after LAT mapping using multipolar mapping catheters with unipolar‐based annotation. Patients were divided into success and failure groups based on ablation success on mapped cardiac surfaces. Discrimination ability, reclassification table, calibration plots, and decision curve analysis of 10 ms EIA (EIA 10ms ), ⊿LAT Bi‐Uni , and LAT Bi were validated. Unipolar morphology was compared between success and failure groups. Results Right ventricular outflow tract, aortic cusp, and left ventricle were mapped in 17, 10, and 8 patients, respectively. In 14/35 (40%) patients, successful ablation was performed on mapped cardiac surfaces. Area under the curve of receiver‐operating characteristic curve of EIA 10ms , ⊿LAT Bi‐Uni , and LAT Bi were 0.874, 0.801, and 0.650, respectively (EIA 10ms vs. LAT Bi , p =.014; ⊿LAT Bi‐Uni vs. LAT Bi , p =.278; EIA 10ms vs. ⊿LAT Bi‐Uni , p =.464). EIA 10ms and ⊿LAT Bi‐Uni demonstrated better predictability, calibration, and clinical utility on reclassification table, calibration plots, and decision curve analysis than LAT Bi . Unipolar morphology of QS or Q pattern did not correlate with ablation success ( p =.518). Conclusion EIA 10ms and ⊿LAT Bi‐Uni more accurately predict ablation success for PVCs on mapped cardiac surfaces than LAT Bi and unipolar morphology.
No takes yet. Share an insight, caveat, or question.
Nagase et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: