Preclinical study demonstrates millisecond-scale sodium signal drops during sensory stimulation in rodents, indicating direct noninvasive mapping of neuronal activity independent of hemodynamics.
Brain-wide, noninvasive methods that directly resolve neuronal activity on millisecond timescales are still lacking in neuroimaging. Hemodynamic fMRI ( 1 H-based) provides whole-brain maps of activity, yet its vascular origin creates spatial and temporal displacements from neuronal events that complicate interpretation, especially in disease conditions where neurovascular coupling is altered. Here, we developed an ultrafast 23 Na fMRI platform at 14 T that combines a reshuffled k-t 3D gradient echo readout (TR/TE, 10ms/1ms) with an implantable RF coil and respiration-gated acquisition. This configuration provides the sampling rate and SNR needed to probe quadrupolar T2*-weighted single quantum sodium dynamics on the neuronal timescale. Across rats and mice, somatosensory forepaw stimulation produced a localized 23 Na signal decrease of ~2-3% in the FP-S1, peaking ~10-30 ms post-stimulus. The activity pattern is well matched with conventional BOLD-fMRI maps acquired in the same animals. Trial-by-trial measurements during simultaneous iGluSnFR glutamate fiber photometry demonstrated that larger evoked glutamate transients coincided with larger NARS decreases, supporting a neuronal origin of the NARS contrast. We interpret the negative NARS response as a transient activity-dependent redistribution of sodium ions toward restricted, protein-rich microdomains, where more restricted rotational dynamics may accelerate T2*short decay and produce a 2-3% signal decrease without requiring large changes in bulk sodium concentration. Together, these results establish neural activity-related sodium (NARS) fMRI as a viable approach for direct, mesoscale neuronal mapping with MRI at millisecond resolution. Graphical Abstract A reshuffled k-t 3D gradient echo (GRE) readout with an implantable figure-8 RF coil and respiration-gated trials captures a ~2-3% negative 23 Na response peaking 10-30 ms after forepaw stimulation in the FP-S1. NARS fMRI responses co-localize with BOLD-fMRI and scale with iGluSnFR glutamate transients, consistent with activity-dependent shifts toward short-T 2 * sodium microenvironments. Table of Contents (TOC) Blurb Yu et al. introduce NARS-fMRI, an ultrafast 23 Na method that resolves millisecond neuronal dynamics in rodent FP-S1. The negative sodium response (10-30 ms) co-localizes with BOLD and correlates with glutamate photometry, supporting a direct neuronal origin.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: