Key result
Empiric permanent pacing cuts costs ~36% and increases QALYs versus implantable cardiac monitors.
Why the study?
Following findings that empiric permanent pacing reduces major adverse events more effectively than an implantable cardiac monitor in syncope and bifascicular block, the cost-effectiveness of these two strategies remained to be determined.
Does empiric permanent pacing improve cost-effectiveness compared to an implantable cardiac monitor in older adults with bifascicular block and syncope?
RCT
Open-label
Does empiric permanent pacing improve cost-effectiveness compared to an implantable cardiac monitor in older adults with bifascicular block and syncope?
Absolute Event Rate: 9918% vs 15416%
Empiric permanent pacing is a dominant, cost-effective strategy compared to implantable cardiac monitors for older patients with unexplained syncope and bifascicular block.
Empiric permanent pacing is dominant and cost-effective; confirms RCT superiority over monitoring for older adults with bifascicular block and syncope.
Background: ears (SPRITELY) trial reported that a strategy of empiric permanent pacing in patients with syncope and bifascicular block reduces major adverse events more effectively than acting on the results of an implantable cardiac monitor (ICM). Our objective was to determine the cost-effectiveness of using the ICM, compared with a pacemaker (PM), in the management of older adults (age > 50 years) with bifascicular block and syncope enrolled in the SPRITELY trial. Methods: SPRITELY was a pragmatic, open-label randomized controlled trial with a median follow-up of 33 months. The primary outcome of this analysis is the cost per additional quality-adjusted life-year (QALY). Resource utilization and utility data were collected prospectively, and outcomes at 2 years were compared between the 2 arms. A decision analytic model simulated a 3-year time horizon. Results: The mean cost incurred by participants randomized to the PM arm was $9918, compared to $15,416 (both in Canadian dollars) for participants randomized to the ICM arm. The ICM strategy resulted in 0.167 QALYs fewer than the PM strategy. Cost and QALY outcomes are sensitive to the proportion of participants randomized to the ICM arm who subsequently required PM insertion. In 40,000 iterations of probabilistic sensitivity analysis, the PM strategy resulted in cost-savings in 99.7% of iterations, compared with the ICM strategy. Conclusions: The PM strategy was dominant-that is, less costly and estimated to result in a greater number of QALYs. For patients with unexplained syncope, bifascicular block, and age > 50 years, a PM is more likely to be cost-effective than an ICM.
No takes yet. Share an insight, caveat, or question.
Hofmeister et al. (2022) conducted an RCT in Syncope and bifascicular block. Pacemaker (PM) vs. Implantable cardiac monitor (ICM) was evaluated on Cost per additional quality-adjusted life-year (QALY). Empiric permanent pacing was dominant over an implantable cardiac monitor strategy, resulting in lower mean costs ($9918 vs $15,416) and 0.167 more QALYs.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: