Key result
iEOA <0.65 cm2/m2 after AVR linked to lower quality of life scores.
Why the study?
Inadequate prosthetic effective orifice area relative to body surface area may impair outcomes, but its impact on health-related quality of life after aortic valve replacement required analysis.
Does an indexed effective orifice area (iEOA) <0.65 cm2/m2 reduce quality of life in patients after aortic valve replacement?
Observational (n=138)
Does an indexed effective orifice area (iEOA) <0.65 cm2/m2 reduce quality of life in patients after aortic valve replacement?
An indexed effective orifice area <0.65 cm2/m2 after aortic valve replacement is significantly associated with impaired postoperative health-related quality of life.
Answers are grounded in this paper and cite their sources.
iEOA <0.65 cm²/m² after AVR was associated with worse QoL; leaves open whether optimizing orifice area improves outcomes in prospective studies.
BACKGROUND: Improving health related quality of life is an important goal of aortic valve replacement. Inadequate effective orifice area of prosthesis according to the patient's body surface area may be associated with poor outcomes. In this study, we aimed to analyze impact of indexed effective orifice area (iEOA) on patients' quality of life after aortic valve replacement. METHODS: A total of 138 patients who underwent isolated aortic valve replacement were included to the study. Quality of life assessment was performed with EuroQol Group EQ-5D-5L questionnaire. Patients were divided into three groups based on iEOA (Group 1 had an iEOA of <0.65 cm2/m2 (19 patients), Group 2 had an iEOA between 0.65-0.85 cm2/m2 (71 patients), and Group 3 had an iEOA of >0.85 cm2/m2). Mean EQ-5D-5L scores were compared among the groups statistically. RESULTS: Mean EQ-5D-5L scores were lower in Group 1 than in Groups 2 and 3 (Group 1: 0.72 ± 0.18, Group 2: 0.83 ± 0.20, and Group 3: 0.86 ± 0.9, p = 0.044 and p = 0.014). The EQ-5D-5L score was significantly lower in patients with a ≥20 mmHg transvalvular gradient than those with a <20 mmHg (0.74 ± 0.25 vs. 0.84 ± 0.18, p = 0.014). CONCLUSIONS: Our results show that an iEOA <0.65 cm2/m2 is significantly associated with impaired postoperative health-related quality of life. Newer generation prostheses, transcatheter valve implantation, and root enlargement techniques should be kept in mind in preoperative planning.
No takes yet. Share an insight, caveat, or question.
Gürsoy et al. (2023) conducted an observational in Aortic valve replacement (n=138). Indexed effective orifice area (iEOA) <0.65 cm2/m2 vs. iEOA ≥0.65 cm2/m2 was evaluated on Mean EQ-5D-5L score (p=0.044). An indexed effective orifice area <0.65 cm2/m2 after aortic valve replacement was associated with lower EQ-5D-5L quality of life scores compared to larger areas.