Key result
Reflex syncope is linked to ~6 mm Hg lower 24-hour systolic BP versus matched controls.
Why the study?
Hemodynamic characteristics in reflex syncope had not been sufficiently explored despite ambulatory BP monitoring emerging as a tool to detect hypotensive susceptibility.
Does 24-hour ambulatory blood pressure monitoring reveal different hemodynamic profiles in patients with reflex syncope compared to matched controls?
Observational (n=150)
Does 24-hour ambulatory blood pressure monitoring reveal different hemodynamic profiles in patients with reflex syncope compared to matched controls?
Patients with reflex syncope exhibit a distinct ambulatory blood pressure profile characterized by lower systolic BP, higher diastolic BP, narrower pulse pressure, and more frequent daytime hypotensive episodes compared to controls.
Answers are grounded in this paper and cite their sources.
May identify distinct BP profile in reflex syncope; hypothesis-generating and requires prospective validation before diagnostic use.
Background Ambulatory blood pressure (BP) monitoring has long been used to monitor BP in hypertension and lately emerged as a useful tool to detect hypotensive susceptibility in reflex syncope. However, hemodynamic characteristics in reflex syncope have not been sufficiently explored. The present study investigated the differences between ambulatory BP monitoring profiles associated with reflex syncope and normal population. Methods and Results This is an observational study comparing ambulatory BP monitoring data from 50 patients with reflex syncope and 100 controls without syncope, age‐ and sex‐matched 1:2. Mean 24‐hour systolic (SBP) and diastolic BP, pulse pressure (24‐hour PP), dipping status, and number of daytime SBP drops <90 to 100 mm Hg were analyzed. Variables associated with reflex syncope were investigated using multivariable logistic regression. Patients with reflex syncope displayed significantly lower 24‐hour SBP (112.9±12.6 versus 119.3±11.5 mm Hg, P =0.002), higher 24‐hour diastolic BP (85.2±9.6 versus 79.1±10.6 mm Hg, P <0.001), and markedly lower 24‐hour PP (27.7±7.6 versus 40.3±9.0 mm Hg, P <0.001) compared with controls. Daytime SBP drops <90 mm Hg were more prevalent in patients with syncope (44% versus 17%, P <0.001). Daytime SBP drops <90 mm Hg, 24‐hour PP <32 mm Hg, 24‐hour SBP ≤110 mm Hg, and 24‐hour diastolic BP ≥82 mm Hg were independently associated with reflex syncope, with 24‐hour PP <32 mm Hg achieving the highest sensitivity (80%) and specificity (86%). Conclusions Patients with reflex syncope have lower 24‐hour SBP but higher 24‐hour diastolic BP and more frequent daytime SBP drops <90 mm Hg than individuals without syncope. Our results support the presence of lower SBP and PP in reflex syncope and suggest a role for ambulatory BP monitoring in the diagnostic work‐up of this condition.
No takes yet. Share an insight, caveat, or question.
Sharad et al. (2023) conducted an observational in Reflex syncope (n=150). Ambulatory blood pressure monitoring vs. Controls without syncope was evaluated on 24-hour systolic blood pressure (mm Hg) (p=0.002). Patients with reflex syncope displayed significantly lower 24-hour systolic blood pressure (112.9 vs 119.3 mm Hg, P=0.002) and pulse pressure compared with matched controls without syncope.
Synapse has enriched 10 related papers. Consider them for comparative context: