Key result
Positive intraoperative fluid balance is linked to greater total body water and absolute fluid overload.
Why the study?
Postoperative water retention and redistribution are linked to adverse outcomes, but non-invasive assessment tools are limited.
Does bio-electrical impedance analysis (BIA) accurately assess perioperative fluid composition and correlate with fluid balance and outcomes in patients undergoing open major abdominal surgery?
Observational (n=71)
Clinician blinded
Does bio-electrical impedance analysis (BIA) accurately assess perioperative fluid composition and correlate with fluid balance and outcomes in patients undergoing open major abdominal surgery?
Bio-electrical impedance analysis is a feasible, non-invasive tool that correlates with intraoperative fluid balance and ICU length of stay in patients undergoing major abdominal surgery.
Answers are grounded in this paper and cite their sources.
Supports BIA for tracking fluid shifts in abdominal surgery; leaves open outcome impact pending prospective trials.
Water retention and intercompartmental redistribution occur frequently in association with adverse postoperative outcomes, yet the available strategies for non-invasive assessment are limited. One such approach for evaluating body water composition in various circumstances is bio-electrical impedance analysis (BIA). This study aims to appraise the usefulness of the Body Composition Monitor (BCM, Fresenius Medical Care, Germany) in assessing body fluid composition and intercompartmental shifts before and after open major abdominal surgery. This prospective, clinician blinded observational study enrolled all the patients scheduled consecutively for elective major open abdominal surgery during a 1-year period starting from January 1st, 2016. BIA parameters—total body water (TBW), extracellular water (ECW), intracellular water (ICW), absolute fluid overload (AFO), and relative fluid overload (RFO) were measured before and after surgery. The results were compared with fluid balance and outcome parameters such as organ dysfunction, ICU-and hospital length of stay (-LOS). The study population included 71 patients aged 60.2 ± 12 of whom 60.6% men and with a BMI of 26.3 ± 5.1 kg/m 2 . Postoperative acute kidney injury, respiratory dysfunction, and infections occurred in 14.0%, 19.7% and 28.1% of cases, respectively. The median LOS in ICU was 20 h and the hospital-LOS was 10 days. Positive intraoperative fluid balance (2.4 ± 1.0 L) resulted in a significant increase of TBW (1.4 ± 2.4 L) and of ECW (1.4 ± 1.2 L). Intraoperative fluid balance significantly correlated with TBW change (r = 0.23, p = 0.04) and with AFO change (r = 0.31, p < 0.01). A significant correlation was found between pre- and postoperative AFO and RFO on one hand, and ICU-LOS on the other. BIA may be a useful tool for the perioperative assessment of volume status.
No takes yet. Share an insight, caveat, or question.
Ciumanghel et al. (2019) conducted an observational in Elective major open abdominal surgery (n=71). Bio-electrical impedance analysis (BIA) was evaluated on Correlation between intraoperative fluid balance and absolute fluid overload (AFO) change (r = 0.31, p=< 0.01). Bio-electrical impedance analysis demonstrated that positive intraoperative fluid balance correlated with changes in total body water and absolute fluid overload.
Synapse has enriched 10 related papers. Consider them for comparative context: