Key result
Higher preablation plasma corin linked to ~47% greater AF recurrence risk per SD.
Why the study?
The study was designed to assess the impact of pre- and postprocedural plasma corin levels on AF recurrence following catheter ablation.
Does elevated preablation plasma corin predict recurrent atrial fibrillation in patients undergoing their first catheter ablation?
Observational (n=616)
No
Does elevated preablation plasma corin predict recurrent atrial fibrillation in patients undergoing their first catheter ablation?
Elevated preablation plasma corin levels independently predict an increased risk of atrial fibrillation recurrence after catheter ablation.
Answers are grounded in this paper and cite their sources.
Corin may refine pre-ablation AF recurrence risk estimates; leaves open whether biomarker-guided strategies improve outcomes.
Background We assessed the impact of pre‐ and postprocedural plasma corin levels on the recurrence of atrial fibrillation (AF) after catheter ablation (CA). Methods and Results This prospective, single‐center, observational study included patients undergoing their first CA of AF. Corin was measured before and 1 day after CA. The primary end point was recurrent AF between 3 and 12 months after ablation. From April 2019 through May 2021, we analyzed 616 patients with AF (59.09% men) with a mean age of 62.86±9.42 years. Overall, 153 patients (24.84%) experienced recurrent AF. In the recurrence group, the pre‐ and postprocedure corin concentrations were 539.14 (329.24–702.08) and 607.37 (364.50–753.80) pg/mL, respectively, which were significantly higher than the nonrecurrence group's respective concentrations of 369.05 (186.36–489.28) and 489.12 (315.66–629.05) pg/mL (both P <0.0001). A multivariate Cox regression analysis with confounders found that elevated preablation corin levels were significantly associated with an increased risk of AF recurrence after CA. Receiver operating characteristic curve analysis identified that a preablation corin threshold of >494.85 pg/mL predicted AF recurrence at 1 year. An increase of 1 SD in corin concentrations before CA (264.94 pg/mL) increased the risk of recurrent AF by 54.3% after adjusting for confounding variables (hazard ratio, 1.465 [95% CI, 1.282–1.655]; P <0.0001). Conclusions Plasma corin levels at baseline is a valuable predictor of AF recurrence after CA, independent of established conventional risk factors. Risk stratification before ablation for AF may be useful in selecting treatment regimens for patients.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2024) conducted an observational in Atrial fibrillation (n=616). Preablation plasma corin levels vs. Lower corin levels was evaluated on Recurrent atrial fibrillation between 3 and 12 months after ablation (HR 1.465, 95% CI 1.282-1.655, p=<0.0001). Elevated preablation plasma corin levels were associated with an increased risk of atrial fibrillation recurrence after catheter ablation.
Synapse has enriched 10 related papers. Consider them for comparative context: