Key result
Volumetric lattice Boltzmann method produces pressure waveforms closely matching clinical measurements in human aortorenal systems.
Why the study?
Inlet and outlet boundary conditions play an important role in newly emerged image-based computational hemodynamics for blood flows in human arteries anatomically extracted from medical images.
The developed physiological boundary conditions for image-based computational hemodynamics provide a reliable method for noninvasive evaluation of hemodynamic abnormalities in diseased human vessels.
May support noninvasive aortorenal pressure assessment; leaves open prospective validation before clinical use.
Inlet and outlet boundary conditions (BCs) play an important role in newly emerged image-based computational hemodynamics for blood flows in human arteries anatomically extracted from medical images. We developed physiological inlet and outlet BCs based on patients’ medical data and integrated them into the volumetric lattice Boltzmann method. The inlet BC is a pulsatile paraboloidal velocity profile, which fits the real arterial shape, constructed from the Doppler velocity waveform. The BC of each outlet is a pulsatile pressure calculated from the three-element Windkessel model, in which three physiological parameters are tuned by the corresponding Doppler velocity waveform. Both velocity and pressure BCs are introduced into the lattice Boltzmann equations through Guo’s non-equilibrium extrapolation scheme. Meanwhile, we performed uncertainty quantification for the impact of uncertainties on the computation results. An application study was conducted for six human aortorenal arterial systems. The computed pressure waveforms have good agreement with the medical measurement data. A systematic uncertainty quantification analysis demonstrates the reliability of the computed pressure with associated uncertainties in the Windkessel model. With the developed physiological BCs, the image-based computation hemodynamics is expected to provide a computation potential for the noninvasive evaluation of hemodynamic abnormalities in diseased human vessels.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2022) studied Hemodynamics in human arteries (n=6). Volumetric lattice Boltzmann method with physiological inlet and outlet boundary conditions vs. Medical measurement data was evaluated on Computed pressure waveforms agreement with medical measurement data. The volumetric lattice Boltzmann method with physiological boundary conditions produced computed pressure waveforms that had good agreement with medical measurement data in six human aortorenal systems.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: