Key result
Drug-induced termination of paroxysmal AF significantly increased mean fibrillation cycle length (from 151 to 203 ms, p<0.001), whereas spontaneous termination patterns depended on the time of day.
Why the study?
Does the mechanism of spontaneous termination of atrial fibrillation differ from drug-induced termination based on changes in fibrillation cycle length?
Observational (n=27)
Does the mechanism of spontaneous termination of atrial fibrillation differ from drug-induced termination based on changes in fibrillation cycle length?
Drug-induced termination of paroxysmal AF depends on a gradual increase in fibrillation cycle length, whereas spontaneous termination patterns depend on the time of day, with morning terminations showing an abrupt increase in cycle length likely related to vagolytic autonomic balance.
Answers are grounded in this paper and cite their sources.
Suggests distinct termination mechanisms in paroxysmal AF; leaves open whether cycle length monitoring aids clinical decisions.
The aim of this study was to investigate the mechanism of spontaneous termination of atrial fibrillation (AF) by comparing it with drug-induced termination on the basis of changes in fibrillation cycle length (FCL). Fast Fourier transform analysis was carried out on the electrocardiogram (ECG) records of 27 patients with paroxysmal AF without organic heart disease. In 8 patients with drug-induced termination of AF, spectral analysis of the data from surface ECG lead V1 was performed before and after class I antiarrhythmic drug infusion for 10 min. In 19 patients with spontaneous termination of AF, the analysis used the Holter ECG recordings at 10 min before the spontaneous termination and at the termination. FCL was calculated from the peak frequency of each epoch and the mean FCL and the coefficient of variation (CV) of FCL were determined from the data of 20 epochs. In the 8 episodes of drug-induced AF termination, the mean FCL increased significantly with class I drugs (from 151+/-17 to 203+/-21 ms, p<0.001), whereas in the 19 episodes of spontaneous termination, the mean FCL and CV of FCL at termination did not differ from those at 10 min before the termination. Of the 19 episodes, 10 episodes terminating in the morning showed a significant increase in the FCL of the last epoch of the termination period (from 158 +/-22 to 172+/-17 ms, p<0.05). In the 9 episodes terminating in either the afternoon or the evening, the FCL of the last epoch did not change significantly. Although drug-induced termination of paroxysmal AF may depend on a gradual increase in FCL, the pattern of spontaneous termination may depend on the time of day. Spontaneous termination in the morning may be caused by an abrupt increase in FCL related to vagolytic autonomic balance.
No takes yet. Share an insight, caveat, or question.
Fujiki et al. (2003) conducted an observational in Paroxysmal atrial fibrillation without organic heart disease (n=27). Class I antiarrhythmic drug infusion vs. Spontaneous termination was evaluated on Fibrillation cycle length (FCL) (p=<0.001). Drug-induced termination of paroxysmal AF significantly increased mean fibrillation cycle length (from 151 to 203 ms, p<0.001), whereas spontaneous termination patterns depended on the time of day.
Synapse has enriched 10 related papers. Consider them for comparative context: