Key result
Percutaneous transluminal coronary angioplasty significantly improved mean transstenotic Doppler flow velocity ratios from <0.60 to >0.90 (P<0.0001).
Why the study?
Does PTCA improve transstenotic Doppler flow velocity ratios in patients with coronary stenoses?
Observational (n=29)
Does PTCA improve transstenotic Doppler flow velocity ratios in patients with coronary stenoses?
Transstenotic Doppler flow velocity ratios significantly improve following successful PTCA, providing a hemodynamic measure of procedural success.
Answers are grounded in this paper and cite their sources.
Supports Doppler ratios as a hemodynamic PTCA success marker; hypothesis-generating for clinical outcomes in observational data.
Doppler probes mounted on the tip of a guidewire allow the measurement of coronary blood flow velocities, not only proximal but also distal to stenoses eligible for percutaneous transluminal coronary angioplasty (PTCA). The objective of this study was to determine the improvement of transstenotic Doppler flow velocity ratios following PTCA and to investigate the possible impact on restenosis during follow-up control angiography three months later. Doppler flow velocity measurements were performed in 29 patients with 29 stenoses eligible for PTCA. Results of PTCA were morphologically evaluated by computer-assisted quantitative coronary angiography (QCA) and measured hemodynamically by determining transstenotic Doppler flow velocity ratios. Successful PTCA according to QCA was present in all cases with a reduction of mean diameter stenosis from 66 +/- 8% to 35 +/- 7%. Resting spectral peak velocities and velocity integrals were markedly reduced distal to lesions (all P < 0.001), resulting in mean transstenotic flow velocity and velocity integral ratios of less than 0.60 prior to PTCA. Owing to endoluminal enlargement, significant improvement of transstenotic Doppler ratios was observed in mean ratios greater than 0.90 (all P < 0.0001). In patients with restenosis, transstenotic ratios following PTCA demonstrated a tendency to be smaller than in patients without restenosis. Transstenotic Doppler flow velocity ratios are diminished in severe coronary stenoses. Improvement of these ratios provides information on hemodynamic success of interventional procedures. Thus, the determination of intracoronary Doppler flow velocity ratios contributes, in addition to angiographic estimation, to the evaluation of stenoses severity and success of interventional procedures.
No takes yet. Share an insight, caveat, or question.
Altstidl et al. (1997) conducted an observational in Coronary stenoses (n=29). Percutaneous transluminal coronary angioplasty (PTCA) vs. Pre-PTCA baseline was evaluated on Transstenotic Doppler flow velocity ratios (p=<0.0001). Percutaneous transluminal coronary angioplasty significantly improved mean transstenotic Doppler flow velocity ratios from <0.60 to >0.90 (P<0.0001).