Key result
Cardiac CT differentiates pannus from thrombus after failed alteplase to guide mechanical mitral valve replacement.
Why the study?
Prosthetic valve thrombosis frequently complicates mechanical valves, and imaging modalities like cardiac CT may help distinguish thrombus from pannus.
Case Report (n=1)
No
Cardiac CT is a valuable imaging modality to distinguish between thrombus and pannus in patients with mechanical prosthetic valve obstruction, guiding appropriate surgical versus medical management.
Answers are grounded in this paper and cite their sources.
Should not yet change management of prosthetic valve obstruction; leaves open role of cardiac CT pending prospective data.
Prosthetic valve thrombosis (PVT) is a frequent complication with a mechanical valve that presents with symptoms of heart failure or thromboembolic episodes. A 45-year-old lady with antiphospholipid syndrome (APS) complicated by a previous history of native mitral valve thrombus and mechanical mitral valve replacement maintained on warfarin presented with complaints of chest pain and shortness of breath (NYHA class 2). The initial lab showed a subtherapeutic international normalized ratio (INR) of 1.8. Transthoracic echo (TTE) showed severe mitral stenosis with a normal ejection fraction of 65%, elevated peak gradient of 34.5 mmHg, mean gradient of 23.7 mmHg, and pressure half time of 214 ms. Cine-fluoroscopic images revealed an immobile posterior mitral valve leaflet. She failed two trials of low-dose alteplase therapy during the hospitalization. Hence cardiac CT with contrast was done, which showed a small degree of pannus formation on the ventricular surface of the mitral valve ring and a small thrombus. Due to persistent immobility of the post mitral valve after two doses of alteplase and a cardiac CT scan concerning pannus formation, a multi-departmental decision was made to proceed with mechanical mitral valve replacement, following which she had a good recovery. Our case report depicts the importance of imaging study, like cardiac CT scan that can help distinguish thrombus (which has a lower Hounsfield unit, HU of <90) vs. pannus (higher HU of more than 145).
No takes yet. Share an insight, caveat, or question.
Shrestha et al. (2022) conducted a case report in Mechanical mitral valve obstruction (n=1). Alteplase and mechanical mitral valve replacement was evaluated on Resolution of mechanical mitral valve obstruction.
Synapse has enriched 10 related papers. Consider them for comparative context: